Liebherr 7083 247-00 Changing over door hinges, Installation dimensions mm, Version

Page 13
Mount door on hinge pin and close.

Changing over door hinges

1.Unscrew the hinge bracket.

Important: The door mounting has a spring mechanism enabling the door to close by itself. The hinge bracket turns to the left when the screws are undone.

2.Pull the door out at the bottom and lift off.

3.Transfer handle and plugs to the opposite side of the door.

4.Transfer pin on hinge bracket to the opposite side.

5. Transfer upper hinge components to the opposite side.

6. Transfer cover plate to the opposite side.

7.

8.Insert hinge bracket in lower door mounting.

9.Turn hinge bracket by 90° - spring is compressed. Screw on hinge bracket.

GB

Installation dimensions (mm)

Version 1

A cross-section of min. 200 cm2 is required­ in the worktop for ventilation of the rear of the appliance.

Version 2

If no ventilation grille is provided in the worktop, the recess must be at least 860 mm high to ensure adequate heat dissipation to the front.

The appliance complies with the relevant safety regulations and EC Directives 2004/108/EC and 2006/95/EC.

25

Image 13
Contents LKUv 7083Disposal notes Appliance dimensionsRange of appliance use Description of the applianceSetting up Safety instructions and warningsSetting the temperature Switching the appliance on and offAudible warning signal Door open alarmDeactivating the audible warning signal function Setting the delay time for the door open alarmAudible warning signal settings Display =Alarm test Alarm messagesAdjusting the alarm parameters Example of an alarm query Resetting the recorded temperature progres- sionSituation Haccp flashes in the display Display = Calibrating the product sensor Calibrating the control sensor standard sensor forActivating the sensor Setting the real time clock Resetting the parameters to factory settingsChanging the network address Setting the display indication for the defrost phase Safety lockCooling DefrostingDo not use steam cleaners because Risk of injury and damage CleaningOpening for external temperature sensor MalfunctionsFloating alarm output External alarmRS485 interface Rx- / TxChanging over door hinges Installation dimensions mmVersion Unscrew the hinge bracket