Multiquip manual EM-120SM Electric Motor, Electric Motor Connection

Page 12

ELECTRIC MOTOR

For lubrication care and operation of the electric motor, refer to your electric motor instruction booklet furnished with the motor.

Protect the electric motor from dust as much as possible and keep ventilating openings clean.

CAUTION:

DO NOT spray water at any time on the electric motor.

DO NOT operate electric motor in a explosive environment.

The electric motor for this mixer is available in either a 5 HP single-phase or 5 HP 3-phase configuration.The input voltage requirement for these motors is either 230VAC or 440VAC only.

ELECTRIC MOTOR CONNECTION

A 12 inch electrical cable (Figure 2) with a pigtail at one end is provided with the electrical motor for hookup to a power source. Table 1. shows the required NEMA connector for the desired motor horsepower rating. In addition, Table 2 also shows the matching NEMA approved connector for the required extension cord.

EM-120SM — ELECTRIC MOTOR

NOTE

It is strongly recommended that all electrical wiring be done by a licensed electrician. Special attention should be given to the electric switch as well as the over-and-under voltage protection devices as per regulations set forth in the local electrical safety code handbook.

Table 2. Electric Motor Wiring Information

Motor

230 Volt - Single Phase

Horsepower

 

 

NEMA Plug Connector

Mating NEMA

Rating

 

Receptacle Connector

 

 

 

 

 

3 HP

L6-20P P/N 940539

L6-20R P/N 940540

 

 

 

5 HP

L6-30P P/N 940547

L6-30R P/N 940548

 

 

 

Figure 2. Single Phase Electric Motor with 12 inch Pigtail Cable

PAGE 12 — ESSICK EM-120SM— OPERATION AND PARTS MANUAL — REV. #5 (03/29/10)

Image 12
Contents Model EM-120SM Page Essick EM-120SM Operation and Parts Manual REV. #5 03/29/10 Table of Contents Parts Ordering Procedures Best Deal! Order via Internet Dealers OnlyOrder via Fax Dealers Only Essick Safety Instructions Operation and Safety DecalsGeneral Safety Rules for Safe OperationMaintenance Safety Rules for Safe OperationEmergencies EM-120SM Specifications EM120SM Mixer SpecificationsEM-120SM General Information EM-120SM Controls MixerElectric Motor Wiring Information EM-120SM Electric MotorElectric Motor Electric Motor ConnectionEM-120SM -TOWING StepCheck the following before towing EM-120SM Paddle Blade Adjustment Paddle Blade Adjustment, Steel DrumEM-120SM Initial START-UP EM-120SM Initial START-UP MixingStarting the Electric Motor Stoppingthe Mixer gasolineEM-120SM Maintenance EM-120SM Maintenance CleaningClutch Adjustment Mechanical 12 CF Mixer Clutch Adjustment ProcedureEM-120SM Maintenance EM-120SM -TROUBLESHOOTING Engine Engine TroubleshootingEM-120SM -TROUBLESHOOTING ENGINE/MIXER Explanation of Code in Remarks Column Items Found In the Remarks ColumnItems Found In the Items Number Column EM-120SM- Suggested Spare Parts EM-120SM 1TO 3 UnitsEM-120SM Mixing Drum Assy EM-120SM Mixing Drum Assy Paddle ShaftEM-120SM Paddle Shaft Assy TOW END Cast Paddle EM-120SM Frame Assy EM-120SM Frame Assy EM-120SM CAB Assy EM-120SM CAB Assy EM-120SM -WISCONSIN Engine Assy EM-120SM -WISCONSIN Engineassy Pilot BushingEM-120SM Honda Engine Assy EM-120SM Honda Engine Assy EM-120SM Electric Motor Assy Bushing EM-120SM -TRANSMISSION Assy Shifter Shaft Special Expediting Service Payment TermsFreight Policy Minimum OrderEssick EM-120SM Operation and Parts Manual REV. #5 03/29/10 HERE’S HOW to GET Help