4.Connect RIM wiring to the terminal block using the terminations shown in Table 5---1.

Table 5---1. RIM Wire Terminations

From RIM A

To SSBM

Remarks

 

 

 

TB1---4

TB3---1

TWISTED WIRES (4)

 

 

TB1---5

TB3---2

1---2 TURNS PER

 

 

TB1---6

TB3---3

3 INCHES

 

 

 

TB1---7

TB3---4

 

 

 

 

From RIM B (if used)

To SSBM

Remarks

 

 

 

TB1---4

TB3---5

TWISTED WIRES (4)

 

 

TB1---5

TB3---6

1---2 TURNS PER

 

 

TB1---6

TB3---7

3 INCHES

 

 

 

TB1---7

TB3---8

 

 

 

 

5.Contact your local field service office for verification and testing of the RIM and its connections prior to making connections to J1---J4.

You can order interface cables separately for connecting to the 15-Pin D-Sub Connectors.

6.Repeat steps 1 through 5 for each RIM you are installing.

7.If you are installing an RMP or SCM in addition to an RIM, proceed to Chapter 4 or 6, respectively; otherwise, secure the SSBM by reversing the steps contained in procedure “To Prepare the SSBM for Wiring to an RMP, RIM, SCM, or Remote EPO” of Chapter 2.