Reversing The Door

All units may be left- or right-hand opening. To reverse the door:

1. Remove travel pin from cabinet

(two screws). See Figure 9.

Slide assembly through flange

and set aside to be used later.

2. Remove top hinge from cabinet (three screws). See Figure 10. Hold door to keep it from falling. Slide hinge through flange.

6. Relocate plastic spacer/

 

bushing on bottom of door to

 

opposite side, and place door

 

on bottom hinge pin. See

Bushing

Figure 14. Clean out bushing

hole in door bottom with a

 

screwdriver if necessary.

 

7. Remove plastic travel pin

 

from door handle and

 

relocate on opposite side.

 

See Figure 15.

 

Hinge

Travel

Pin Hole

14

Travel

Pin Hole

3. Lift the door off the bottom hinge.

4. Remove bottom hinge from

9

 

Screw

 

Right Side

 

 

Door Swing

 

 

Right Side

Invert

Invert

Hinge

Screw

Hinge

Left Side

Door Swing

15

8.Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge. See Figure 16.

10

11

cabinet (two screws). See Figure 11. Remove screws on opposite side of cabinet (Figure 12). Note that there may be a nut behind one or both screws on either side.

1213

5.Install hinge on opposite side, bottom of cabinet. See Figure 13. Replace nut on back side where installed. Align hinge outer edge with cabinet before tightening screws.

1617

9.Gently slide upper hinge through flange and fasten upper hinge to unit (three screws). Partially tighten screws. See Figure 17.

10.Place door on lower hinge pin.

11.Align door pivot hole with

pivot hole in upper hinge and insert pivot screw into upper hinge and tighten securely.

See Figure 18.

12.

Adjust door to assure proper

 

 

seal. Tighten upper and lower

 

 

hinge screws securely.

 

13.

Gently slide travel pin

 

 

assembly through flange and

18

 

then fasten to unit. Make sure

 

 

travel pin in door engages the closer in the assembly, then tighten screws on travel pin assembly securely.

U-Line Door Reversal

10

Image 11
Contents Install Guide Table of Contents Safety Precautions Safety Alert DefinitionsGeneral Precautions Inspect & Plan Exterior CleaningProduct Registration Models Covered Tools / Material RequiredPrepare Site Cut-Out DimensionsUnits can not be installed behind a closed cabinet door BI95BTP BI98 BI2115 Product DimensionsADA15IM Series ADA15IM Stainless Series BI95B & BI95WH SS1095NF SS1095FD SS1095FC SP18Environmental Requirements Door Swing DimensionsPower Supply Water SupplyReversing the Door BI95 & BI98Door Reversal 1617 WH95TP, BI95BTP, BCM95 & SP18See Figure 12132324 SS1095Underneath the hinge to the opposite hole in top cap Page Door Panel Preparation Panel DimensionsDoor Panel Installation 98, SP18, & ADA15 Door Panel InstallationPower Supply Adjusting Door AlignmentElectrical Specifications Adjust DoorPlumbing Water Supply ConnectionLeveling Information InstallationGrille Installation InstallBI-2115 Specific Installation TroubleshootingInstallation Guide