U-Line ADA15IM Door Swing Dimensions, Power Supply, Water Supply, Environmental Requirements

Page 9

Door Swing Dimensions

All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 2" to accommodate the handle if the unit is installed next to a wall or similar type of structure.

Wall

ADA15IM Series

Wall

1/4" Min.

 

2" Min.

 

20-7/8"

20-7/8"

 

16-1/2"

16-1/2"

Door Swing

 

Door Swing

(Without Handle)

 

(With Handle)

BI98

 

SP18

Wall

 

Wall

 

 

1/4" Min.

 

3/4" Min.

 

 

 

17-3/8"

22"

 

 

15-1/8"

90°

16-1/2"

15-1/2"

 

Door Swing

 

90°

 

 

Door Swing

6 Other Site Requirements

Power Supply

Units requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 14.

Water Supply

Units require a 1/4” OD water supply line and a shut off valve. For more information see page 15

Environmental Requirements

Units are designed to operate between 50°F (10°C) and 100°F (37°C). High ambient temperatures (100°F [37°C] or higher) may reduce the unit’s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers.

If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the unit to prevent freezing damage, which is not covered by the warranty.

For best performance, keep the unit out of direct sunlight and away from heat generating equipment.

For best performance and life outdoors, place under a counter or provide shelter of some kind.

In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

.

SS1095NF

SS1095FC/FD

WH95, BI95BTP, BCM95

Wall

Wall

1/4" Min.

3/4" Min.

14-3/8"

14-3/8"

90°

15-1/2"

15-1/2"

Door Swing

 

 

90°

 

 

 

 

 

Door Swing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other Site Requirements

8

Image 9
Contents Install Guide Table of Contents Safety Alert Definitions General PrecautionsSafety Precautions Product Registration Models Covered Exterior CleaningTools / Material Required Inspect & PlanCut-Out Dimensions Units can not be installed behind a closed cabinet doorPrepare Site BI95BTP ADA15IM Series Product DimensionsADA15IM Stainless Series BI95B & BI95WH BI98 BI2115SS1095FC SS1095FDSP18 SS1095NFPower Supply Door Swing DimensionsWater Supply Environmental RequirementsBI95 & BI98 Door ReversalReversing the Door See Figure WH95TP, BI95BTP, BCM95 & SP181213 1617SS1095 Underneath the hinge to the opposite hole in top cap2324 Page Door Panel Installation 98, SP18, & ADA15 Panel DimensionsDoor Panel Installation Door Panel PreparationElectrical Specifications Adjusting Door AlignmentAdjust Door Power SupplyPlumbing Water Supply ConnectionGrille Installation InstallationInstall Leveling InformationBI-2115 Specific Installation TroubleshootingInstallation Guide