911 Plumbing

CAUTION

Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.

Water Supply Connection

When connecting the water supply, follow these guidelines:

Review the local plumbing codes before you install the unit.

Connect to the cold water supply.

The water pressure should be between 20 and 120 psi.

The water line MUST have a shut-off valve in the 1/4” O.D. supply line.

Leave approximately 8’ of water line to be coiled behind the appliance. The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and servicing. However, make certain that the tubing is not pinched or damaged during installation.

IMPORTANT

U-Line requires the use of copper tubing for installation. Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause water damage to your home.

1.For units with front mounted water solenoids you must remove the grille

1.Install the 1/4 inch OD copper water line to the main water source.

2.Locate the compression fitting and

ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch OD water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line.

3.Carefully bend the water supply line into position and connect the line to the solenoid valve. Avoid kinking the water supply line.

IMPORTANT

For units with front mounted water solenoids, route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve. Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line.

Front Mount

 

Rear Mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

Connection

Water Line

4.For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area. This will also safeguard against kinking the line.

U-Line Other Requirements

15

Image 16
Contents Install Guide Table of Contents General Precautions Safety Alert DefinitionsSafety Precautions Exterior Cleaning Product Registration Models CoveredTools / Material Required Inspect & PlanUnits can not be installed behind a closed cabinet door Cut-Out DimensionsPrepare Site BI95BTP Product Dimensions ADA15IM SeriesADA15IM Stainless Series BI95B & BI95WH BI98 BI2115SS1095FD SS1095FCSP18 SS1095NFDoor Swing Dimensions Power SupplyWater Supply Environmental RequirementsDoor Reversal BI95 & BI98Reversing the Door WH95TP, BI95BTP, BCM95 & SP18 See Figure1213 1617Underneath the hinge to the opposite hole in top cap SS10952324 Page Panel Dimensions Door Panel Installation 98, SP18, & ADA15Door Panel Installation Door Panel PreparationAdjusting Door Alignment Electrical SpecificationsAdjust Door Power SupplyWater Supply Connection PlumbingInstallation Grille InstallationInstall Leveling InformationInstallation Troubleshooting BI-2115 SpecificInstallation Guide