Instructions for the installer
4.2 Burner and nozzle characteristics table (60 cm model);
| Rated heating |
|
|
|
|
|
|
Burner | capacity (kW) |
| LIQUID GAS – G30/G31 28/37 mbar |
|
| ||
|
|
|
|
|
|
|
|
|
| Nozzle | Reduced | Capacity | Capacity |
| |
|
| diameter 1/ | 1/100 | capacity | g/h G30 | g/h G31 |
|
|
| 100 mm | mm | (W) |
|
|
|
|
|
|
|
|
|
|
|
Auxiliary | 1.0 | 50 | 30 | 400 | 73 | 71 |
|
Semi rapid | 1.8 | 65 | 33 | 500 | 127 | 125 |
|
4.0 | 100 | 65 | 1600 | 290 | 286 |
| |
Oven | 3.2 | 87 | 50 | 900 | 233 | 229 |
|
| Rated heating |
|
|
|
|
|
|
Burner | capacity (kW) |
| LIQUID GAS – G30/G31 28/37 mbar |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Rated heating |
|
|
|
|
|
|
Burner | capacity |
| TOWN GAS – G110 8 mbar |
|
| ||
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle |
| Reduced |
|
|
|
|
| diameter |
| capacity |
|
|
|
|
| 1/100 mm |
| (W) |
|
|
|
|
|
|
|
|
|
|
Auxiliary | 1.0 |
| 145 (/8) |
| 400 |
|
|
Semi rapid | 1.8 |
| 185 (/2) |
| 500 |
|
|
Triple crown | 4.0 |
| 350 (/13) |
| 1200 |
|
|
Oven | 3.2 |
| 270 |
| 900 |
|
|
The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.
| Rated heating |
|
|
Burner | capacity | NATURAL GAS – G20/G25 20/25 mbar | |
| (kW) |
|
|
|
|
|
|
|
| Nozzle | Reduced |
|
| diameter | capacity |
|
| 1/100 mm | (W) |
|
|
|
|
Auxiliary | 1.0 | 72 (X) | 400 |
Semi rapid | 1.8 | 97 (Z) | 500 |
4.0 | 135 (K) | 1600 | |
Oven | 3.2 | 130 | 900 |
|
|
|
|
81