Instructions for the installer
5. FINAL OPERATIONS
After replacing the nozzles, reposition the
Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. The label is inserted inside the pack together with the nozzles.
5.1 Regulation of the hob burners minimum for natural gas
Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.
Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.
For models with valves, keep the knob at minimum level for a few seconds to keep the flame lit and to activate the safety device.
5.2 Regulation of the hob burners minimum for liquid gas
In order to adjust the minimum with liquid gas, the screw at the side of the tap rod must be tightened clockwise all the way.
The bypass diameters for each individual burner are shown in paragraph “4.2 Burner and nozzle characteristics table (60 cm model);”. When the adjustment is completed, restore the sealing of the by- passes with paint or other material.
5.3 Positioning and levelling the appliance (depending on the model)
After making the electrical and gas connections, level the appliance on the floor by means of its four adjustable feet. For good cooking results, the appliance must be properly levelled.
Depending on the model you have purchased, the foot height adjustment range may vary from 70 to 95
mmand from 110 to 160mm. These heights refer to the distance between the highest point of the foot (fixed part) and the lowest point (movable part which rests on the floor).
5.4 Adjustment of the oven burner minimum
Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.
Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.
84