Smeg C6GVXI manual Final Operations, Regulation of the hob burners minimum for natural gas

Page 13

Instructions for the installer

5. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. The label is inserted inside the pack together with the nozzles.

5.1 Regulation of the hob burners minimum for natural gas

Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for a few seconds to keep the flame lit and to activate the safety device.

5.2 Regulation of the hob burners minimum for liquid gas

In order to adjust the minimum with liquid gas, the screw at the side of the tap rod must be tightened clockwise all the way.

The bypass diameters for each individual burner are shown in paragraph “4.2 Burner and nozzle characteristics table (60 cm model);”. When the adjustment is completed, restore the sealing of the by- passes with paint or other material.

5.3 Positioning and levelling the appliance (depending on the model)

After making the electrical and gas connections, level the appliance on the floor by means of its four adjustable feet. For good cooking results, the appliance must be properly levelled.

Depending on the model you have purchased, the foot height adjustment range may vary from 70 to 95

mmand from 110 to 160mm. These heights refer to the distance between the highest point of the foot (fixed part) and the lowest point (movable part which rests on the floor).

5.4 Adjustment of the oven burner minimum

Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.

84

Image 13
Contents Contents Manufacturer Declines ALL Responsibility for Improper USE Instructions for USEPrecautions for use Instructions for Disposal OUR Environmental Care Installing the Appliance Room ventilation Electrical connectionExtraction of the products of combustion Connection with a rubber hose Connection to gasConnection to natural and town gas Connection to liquid gasConnection with flexible steel hose for all types of gas Adaptation to Different Types of GAS Replacement of nozzles on the cooking hob100 Capacity G30 G31 100 mm Burner and nozzle characteristics cm modelBurner Capacity kW Liquid GAS G30/G31 28/37 mbar Burner Capacity Town GAS G110 8 mbarInstructions for the installer Arrangement of the burners on the cooking hob Oven burner adjustment only for models with a gas ovenBurners Natural GASFinal Operations Adjustment of the oven burner minimumRegulation of the hob burners minimum for natural gas Regulation of the hob burners minimum for liquid gasControl Panel Timer KnobHOB Burners Control Knob GAS Oven Thermostat KnobFunctions Selection Knob Practical hints for using the hob burners Using the Cooking HOBLighting the hob burners 90 cm cookers pan diameters 60 cm cookers pan diametersUsing the gas oven Using the OvenCooling fan Electronic spark ignitionHow to use the grill Using the electric grillPrecautions Storage compartment only on some modelsBaking plate on some models only useful for cooking cakes Available AccessoriesOrdinary daily cleaning Cleaning and MaintenanceCleaning the parts of the cooking hob Food stains or residuesCleaning the door glazing Cleaning the ovenBurner caps and flame spreader crowns Igniters and thermocouplesExtraordinary Maintenance