4.3 Burner and nozzle characteristics table (90 cm model);

 

Rated heating

 

 

 

 

 

 

Burner

capacity (kW)

 

LIQUID GAS – G30/G31 28/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

By-pass

Reduced

Capacity

Capacity

 

 

 

diameter 1/

1/100

capacity

g/h G30

g/h G31

 

 

 

100 mm

mm

(W)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

50

30

400

73

71

 

Semi rapid

1.8

65

33

500

127

125

 

Rapid

3.0

85

45

800

218

214

 

Ultra-rapid

4.0

100

65

1600

291

286

 

Maxi oven

5.2

110

59

1300

378

371

 

 

 

 

 

 

 

 

 

 

Rated heating

 

 

 

 

 

 

Burner

capacity

 

TOWN GAS – G110 8 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

Reduced

 

 

 

 

 

diameter

 

capacity

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

 

145 (/8)

 

400

 

 

Semi rapid

1.8

 

185 (/2)

 

500

 

 

Rapid

3.0

 

260 (/3)

 

800

 

 

Triple crown

4.0

 

350 (/13)

 

1200

 

 

The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.

 

Rated heating

 

 

Burner

capacity

NATURAL GAS – G20/G25 20/25 mbar

 

(kW)

 

 

 

 

 

 

 

 

Nozzle

Reduced

 

 

diameter

capacity

 

 

1/100 mm

(W)

 

 

 

 

Auxiliary

1.0

72

400

Semi rapid

1.8

97

500

Rapid

3.0

115

800

Ultra-rapid

4.0

135

1500

Maxi oven

5.2

164

1300

 

 

 

 

82

Image 11
Contents Contents Manufacturer Declines ALL Responsibility for Improper USE Instructions for USEPrecautions for use Instructions for Disposal OUR Environmental Care Installing the Appliance Extraction of the products of combustion Electrical connectionRoom ventilation Connection to liquid gas Connection to gasConnection with a rubber hose Connection to natural and town gasConnection with flexible steel hose for all types of gas Adaptation to Different Types of GAS Replacement of nozzles on the cooking hobBurner Capacity Town GAS G110 8 mbar Burner and nozzle characteristics cm model100 Capacity G30 G31 100 mm Burner Capacity kW Liquid GAS G30/G31 28/37 mbarInstructions for the installer Natural GAS Oven burner adjustment only for models with a gas ovenArrangement of the burners on the cooking hob BurnersRegulation of the hob burners minimum for liquid gas Adjustment of the oven burner minimumFinal Operations Regulation of the hob burners minimum for natural gasGAS Oven Thermostat Knob Timer KnobControl Panel HOB Burners Control KnobFunctions Selection Knob Lighting the hob burners Using the Cooking HOBPractical hints for using the hob burners 90 cm cookers pan diameters 60 cm cookers pan diametersElectronic spark ignition Using the OvenUsing the gas oven Cooling fanStorage compartment only on some models Using the electric grillHow to use the grill PrecautionsBaking plate on some models only useful for cooking cakes Available AccessoriesFood stains or residues Cleaning and MaintenanceOrdinary daily cleaning Cleaning the parts of the cooking hobIgniters and thermocouples Cleaning the ovenCleaning the door glazing Burner caps and flame spreader crownsExtraordinary Maintenance