Traulsen TU100HT, TU044LT, TU072HT, TU072LT VII. Microprocessor Control, VII. b Alarm Explanations

Page 7

VII. MICROPROCESSOR CONTROL (continued)

VII. b - ALARM EXPLANATIONS:

*NOTE: Explanation of alarms assume the audible alarm style is set at a 3-second burst or a continuous audible alarm. References to the audible alarm do not apply if the audible alarm style is set to OFF (Refer to page 16 for setting the audible alarm style).

High Cabinet Air Temperature: The audible alarm will sound and the display will read HI CAb when the temperature inside the cabinet rises above a pre-programmed limit. The limit is determined by the type of unit being operated (i.e.: refrigerator/freezer). To turn off the audible alarm, press the alarm cancel button. The visual alarm text will continue to display until the cabinet air temperature falls below the limit. If the temperature does not fall below the limit within 5 minutes, the audible alarm* will sound again and an additional Call Service message will display.

POSSIBLE CAUSES:

Doors open for extended periods of time.

Large amounts of hot product placed inside the cabinet.

Condenser coil dirty.

Cooling Compressor Failure. Call Service.

Refrigeration Problems.

Low Cabinet Air Temperature: The audible alarm will sound and the display will read Lo Cab when the temperature inside the cabinet falls below a pre-programmed limit. The limit is determined by the type of unit being operated (i.e.: refrigerator/ freezer). To turn off the audible alarm, press the alarm cancel button. The visual alarm text will continue to display until the cabinet air temperature rises above the limit. If the temperature does not rise above the limit within 5 minutes, the audible alarm will sound again and an additional Call Service message will display.

POSSIBLE CAUSES:

No product in unit.

Failed sensors.

Stuck Evaporator Relay.

Loss Of Power: The audible alarm will sound and the display will read ELE LOS, when the unit regains power after an outage. To turn off the audible alarm and/or clear the visual text, press the alarm cancel button.

Condenser Clean: The audible alarm will sound and the display will read “Clean Filter” when discharge temperatures exceeds 140 degrees. As the load on the condenser decreases, the alarm will turn off by itself. As the temperature on the condenser continue to rise, the audible alarm will return until the problem has been eliminated.

NOTE: If discharge temperature rises above 1600F the compressor & condenser fan motor will be switched off until the discharge temp falls below 1400F

Sensor Failures:

The audible alarm will sound and the display will read CAB SEN, COL SEN or DIS SEN when that particular sensor has failed to operate. To turn off the audible alarm, press the alarm cancel function of the sensor, the audible alarm will sound again in either 5 minutes or 24 hours. Note: Test sensor in ice water.

-6-

Image 7
Contents Quality Refrigeration Serial TAG Table of ContentsII. Receipt Inspection III. InstallationIV. b Freezers Cleaning the CONDENSER/FILTERIV. Operation IV. a RefrigeratorsCleaning the Cabinet Surfaces VI. a Removing the Door and Installing DrawersReplacing the Gaskets VII. Microprocessor Control VII. Microprocessor Control VII. b Alarm ExplanationsVII. d Notes to the User VII. c Control Panel DiagramVII. e Enter the Service Access VII. g Adjusting Thermostat SET Point High VII. f Service ParametersVII. i Changing the Temperature Scale VII. h Adjusting Thermostat SET Point LOWVII. j Setting the 24-HOUR Clock VII. l Setting Daylight Savings Time VII. k Setting the DateVII. m Starting a Manual Defrost Cycle Sample VII. n Setting the Defrost LockoutsVII. p Adjusting the Room Temperature Offset VII. o Adjusting the Drawer Perimeter HeatersVII. r Viewing Sensor Temperatures VII. q Setting the Audible Alarm StyleVIII. Wiring Diagram Problem Possible Solution IX. Trouble Shooting GuideSpare Parts Information Service AssistanceService Information Warranty RegistrationXI. Warranties Standard Domestic WarrantyDoor ALL Models XII. Service Parts ListPage Quality Refrigeration

TU044HT, TU072LT, TU100HT, TU072HT, TU044LT specifications

Traulsen, a leader in commercial refrigeration, offers a range of innovative products designed to meet the needs of food service operators. Among these, the TU044LT, TU072HT, TU100HT, TU072LT, and TU044HT models stand out for their efficiency, reliability, and advanced features.

The TU044LT is a low-temperature undercounter freezer that delivers exceptional performance in compact spaces. With a capacity of 44 cubic feet, it is ideal for restaurants with limited storage. Its energy-efficient design ensures lower operational costs, while the stainless steel exterior offers durability and easy cleaning. Equipped with advanced digital controls, this freezer maintains consistent temperatures, ensuring your ingredients remain fresh and safe.

Next in line is the TU072HT, a high-temperature unit designed for maximum efficiency. It provides ample storage with a capacity of 72 cubic feet and features a robust refrigeration system that operates quietly. The TU072HT is perfect for storing bulk ingredients, thanks to its adjustable shelving, which offers flexibility for users. Additionally, its self-closing doors enhance energy efficiency and help maintain the optimal internal temperature.

The TU100HT model takes this a step further with an even larger capacity of 100 cubic feet, making it ideal for high-volume establishments. Its advanced insulation technology ensures minimal energy consumption while maintaining superior temperature control. The TU100HT also comes equipped with a digital temperature display, allowing users to monitor and adjust settings easily. The heavy-duty construction ensures longevity, even in the busiest kitchens.

For those seeking a combination of features, the TU072LT provides both low-temperature and ample storage space. This model combines the technological advancements of Traulsen with a practical design, offering a significant 72 cubic feet of storage. Its eco-friendly refrigerant reduces environmental impact while ensuring maximum efficiency.

Lastly, the TU044HT model is a high-temperature reach-in unit with a compact design that does not compromise on capacity. This freezer is engineered to provide reliable performance with a focus on energy efficiency. The adjustable shelving and LED lighting improve visibility and accessibility, making it a practical choice for busy restaurants.

In summary, the Traulsen TU044LT, TU072HT, TU100HT, TU072LT, and TU044HT models exemplify quality and innovation in commercial refrigeration. With their varied capacities and cutting-edge technologies, these units are designed to enhance operational efficiency, reduce energy costs, and maintain the integrity of food products in any food service operation.