Whirlpool W10258095A installation instructions Terminal block Line Red wire

Page 10

6.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the #10-32 hex nuts.

G

A

B

 

 

F

 

D

E

C

 

 

 

A. #10-32 hex nut

 

E. Neutral (white) wire

B. Line 1 (black)

 

F. Line 2 (red)

C. Bare (green) ground wire

G. Terminal lug

D.Ground-link screw

7.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with #10-32 hex nuts.

8.Securely tighten hex nuts.

9.Replace terminal block access cover.

3-wire connection: Direct Wire

Use this method only if local codes permit connecting ground conductor to neutral supply wire.

1.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A

 

 

 

B

 

 

 

C

 

 

 

D

F

E

 

 

 

 

 

A. Terminal block

 

D. Line 2

(red) wire

B. Ground-link screw

 

E. Bare (green) ground wire

C. Cord/conduit plate

F. Line 1

(black) wire

2.Attach terminal lugs to line 1 (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to torque as shown in the following Bare Wire Torque Specifications chart.

A

B

C D E

A. Terminal lug

B. Set screw

C. Line 1 (black) wire

D. Bare (green) ground wire

E. Line 2 (red) wire

Bare Wire Torque Specifications

Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

Wire Awg

Torque

8 gauge copper

25 lbs-in. (2.8 N-m)

 

 

6 gauge aluminum

35 lbs-in. (4.0 N-m)

 

 

3.Use ³⁄₈" nut driver to connect the bare (green) ground wire to the center terminal block post with one of the #10-32 hex nuts.

F

A

E

B

 

D

 

C

A. #10-32 hex nut

D. Bare (green) ground wire

B. Line 1 (black)

E. Line 2 (red)

C. Ground-link screw

F. Terminal lug

4.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with #10-32 hex nuts.

5.Securely tighten hex nuts.

6.Replace terminal block access cover.

10

Image 10
Contents Range Safety Table of ContentsTools and Parts Installation RequirementsLocation Requirements Electrical Requirements Cabinet DimensionsIf connecting to a 4-wire system Electrical ConnectionUnpack Range Installation InstructionsIf connecting to a 3-wire system On Ranges Equipped with Storage DrawersFloor Mounting Install Anti-Tip BracketWall Mounting Style 1 Power supply cord strain relief Power Supply CordDirect Wire Style 2 Direct wire strain reliefWire connection Power Supply Cord #10-32 hex nut Green ground wire Ground-link screw Bare Wire Torque Specifications Direct Wire Installation Copper or Aluminum WireWire Connection Direct Wire Wire Awg TorqueTerminal block Line Red wire Verify Anti-Tip Bracket Location Complete InstallationIf you need Assistance or Service Level RangeMoving the Range For power supply cord-connected rangesFor direct-wired ranges W10258095A