Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required
1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.
1"
(2.5 cm)
3"
(7.6 cm)
2.Allow enough slack in the wire to easily attach the wiring terminal block.
3.Complete electrical connection according to your type of electrical supply
4-wire Connection: Direct Wire
Use this method for:
■New
■Mobile homes
■Recreational vehicles
■In an area where local codes prohibit grounding through the neutral
1.Part of metal ground strap must be cut out and removed.
A
B
C
A. Metal ground strap
B.Discard
C.
2.Use Phillips screwdriver to remove the
3.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.
A
| B |
| C |
G | D |
| |
F | E |
| |
A. Terminal block | E. Neutral (white) wire |
B. | F. Line 1 (black) wire |
C. Cord/conduit plate | G. Bare (green) ground wire |
D. Line 2 (red) wire |
|
4.Attach terminal lugs to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to torque as shown in the following Bare Wire Torque Specifications chart.
A
B
C D E
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20
Wire Awg | Torque |
8 gauge copper | 25 |
|
|
6 gauge aluminum | 35 |
|
|
5.Use Phillips screwdriver to connect the bare (green) ground wire to the range with the
9