Whirlpool W10258095A Direct Wire Installation Copper or Aluminum Wire, Wire Awg Torque

Page 9

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection.

1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.

1"

(2.5 cm)

3"

(7.6 cm)

2.Allow enough slack in the wire to easily attach the wiring terminal block.

3.Complete electrical connection according to your type of electrical supply (4-wire or 3-wire connection).

4-wire Connection: Direct Wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the neutral

1.Part of metal ground strap must be cut out and removed.

A

B

C

A. Metal ground strap

B.Discard

C.Ground-link screw

2.Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw and the end of the ground link under the screw.

3.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.

A

 

B

 

C

G

D

 

F

E

 

A. Terminal block

E. Neutral (white) wire

B. Ground-link screw

F. Line 1 (black) wire

C. Cord/conduit plate

G. Bare (green) ground wire

D. Line 2 (red) wire

 

4.Attach terminal lugs to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to torque as shown in the following Bare Wire Torque Specifications chart.

A

B

C D E

A. Terminal lug

B. Set screw

C. Line 1 (black) wire

D. Neutral (white) wire

E. Line 2 (red) wire

Bare Wire Torque Specifications

Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

Wire Awg

Torque

8 gauge copper

25 lbs-in. (2.8 N-m)

 

 

6 gauge aluminum

35 lbs-in. (4.0 N-m)

 

 

5.Use Phillips screwdriver to connect the bare (green) ground wire to the range with the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

9

Image 9
Contents Table of Contents Range SafetyInstallation Requirements Tools and PartsLocation Requirements If connecting to a 4-wire system Cabinet DimensionsElectrical Requirements Electrical ConnectionIf connecting to a 3-wire system Installation InstructionsUnpack Range On Ranges Equipped with Storage DrawersInstall Anti-Tip Bracket Floor MountingWall Mounting Direct Wire Power Supply CordStyle 1 Power supply cord strain relief Style 2 Direct wire strain reliefWire connection Power Supply Cord #10-32 hex nut Green ground wire Ground-link screw Wire Connection Direct Wire Direct Wire Installation Copper or Aluminum WireBare Wire Torque Specifications Wire Awg TorqueTerminal block Line Red wire If you need Assistance or Service Complete InstallationVerify Anti-Tip Bracket Location Level RangeFor direct-wired ranges For power supply cord-connected rangesMoving the Range W10258095A