The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper
2
1
1
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed,
INSTALLATION INSTRUCTIONS
Unpack Range
WARNING
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1.Remove shipping materials, tape and film from range.
2.Remove oven racks and parts package from inside oven.
3.Do not remove the shipping base at this time.
A
A. Shipping base
4.On Ranges Equipped with Storage Drawers:
Remove the storage drawer. If a range height adjustment is necessary, use a ¼" drive ratchet to lower the rear leveling legs
A
D
C
B
A. ¼" drive ratchet
B. Rear leveling leg
C. Wrench or pliers
D. Front leveling leg
On Ranges Equipped with Warming Drawers:
If a range height adjustment is necessary, use wrench or pliers to lower the front and rear leveling legs.
A B
C
A. Rear leveling leg B. Front leveling leg C. Wrench or pliers
4