Goldstar MA-2005ST Interlock Continuity Test, Primary Interlock Switch Test, Monitor Switch Test

Page 29

INTERLOCK CONTINUITY TEST

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.

TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH

TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH

TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH

A. PRIMARY INTERLOCK SWITCH TEST

When the door release button is depressed slowly with the door closed, an audible click should be heard at the same time or successively at intervals. When the button is released slowly, the latches should activate the switches with an audible click.

If the latches do not activate the switches when the door is closed, the switches should be a adjusted in accordance with the adjustment procedure. Disconnect the wire lead from the primary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminal of the switch. The meter should indicate an open circuit in the door open condition. When the door is closed, the meter should indicate a closed circuit.

When the primary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

B. SECONDARY INTERLOCK SWITCH TEST

Disconnect the wire lead from the secondary switch.

Connect the ohmmeter leads to the common (COM) and normally open (NO) terminals of the switch. The meter should indicate a open circuit in the door open condition. When the door is closed, meter should indicate an closed circuit. When the secondary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

C. MONITOR SWITCH TEST

Disconnect the wire lead from the monitor switch. Connect the ohmmeter leads to the common (COM) and normally closed (NC) terminals of the switch. The meter should indicate closed circuit in the door open condition. When the door is closed, meter should indicate an open circuit. When the monitor switch operation is abnormal, replace with the same type of switch.

NOTE: After repairing the door or the interlock system, it is necessary to do this continuity test before operating the oven.

COMPONENTS

 

TEST PROCEDURE

RESULTS

 

SWITCHES

Check for continuity of the

 

Door

Door

(Wire leads removed)

switch with an Ohm-meter

 

open

closed

 

Primary

 

NO

 

 

 

Switch

 

 

 

 

COM

 

 

 

 

Monitor

 

NC

 

 

 

Switch

COM

 

 

 

 

Secondary

 

 

 

 

Switch

COM

NO

 

 

 

 

 

 

 

 

NOTE : After checking for the continuity of switches, make sure that they are

 

 

connected correctly.

 

 

5-7

Image 29
Contents Microwave Oven Safety Precautions Type of Microwave Oven Function & Type 1/2How a Microwave Oven Works Grill Cooking Function & Type 2/2Installation Installation & Utensils 1/2Cooking Utensils Installation & Utensils 2/2Principle of dielectric heating What’s the microwave? 1/2History of dielectric heating Definition of electric wave Safety of microwave ovenWhat’s the microwave? 2/2 Conventional heating Conventional heating vs. dielectric heatingCavity Construction of microwave ovenDoor ControllerHow does the microwave oven operate? Input Senondary Winding AT Microwave generation systemMagnetron 1/2 Microwave generation systemMagnetron 2/2 Testing Magnetron TubeMultiwave system What is Multi-WaveWhat’s the infrared sensor? Infrared sensorWhat’s does move automatically? Auto moving heaterConventional Heater LG’s Auto Moving HeaterSpecifications Control Panel FeaturesOperating Sequence Schematic Circuit Description Microwave Leakage Test Tools and Measuring InstrumentsNecessary Tools Necessary Measuring InstrumentsRecord Keeping and Notification After Measurement Measurement with Outer Case RemovedMeasurement with a Fully Assembled Oven Disassembly and Adjustment Measurement of Microwave Power OutputPower Supply Cord Control Panel AssemblyDoor Main Assembly Removal PCB Assembly RemovalRemoving the Turntable Motor AIR Duct Assembly RemovalMagnetron Removal High Voltage Transformer Removal FAN Motor Assembly RemovalHigh Voltage Capacitor and Diode Removal Interlock SystemSecondary Interlock Switch Test Primary Interlock Switch TestMonitor Switch Test Interlock Continuity TestComponents Test Procedure Component Test ProcedureComponents Test Procedure Results Relay Condition Cause Remedy Trouble ShootingResult Result Condition Check Defective PCB assembly Defective high voltage transformer Introduction Exploded ViewDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts Interior Parts Base Plate Parts Schematic Diagram of P.C.B Printed Circuit Board