Creda E010E, R010E manual Oven Unit Housing Cabinets, Electrical Installation, Mains Supply

Page 31

Installation Instructions

2.Oven Unit Housing Cabinets

(a)The oven unit housing cabinet dimensions must comply with Fig. 3 and Fig. 4.

(b)An air gap of 50mm minimum must be provided at the rear of any top or bottom cupboards or shelves for ventilation.

(c)Do not obstruct the ventilation slots provided on the oven trim. This is found adjacent to the bottom of the oven door.

(d)The air gap at the rear allows the warmed air to pass out of the cabinet. If cabinets extend up to the ceiling, the warm air must be exhausted through to the front. Fig. 1.

(e)If an oven unit is installed adjacent to a tall cabinet, steam escaping from the oven when the door is opened could condense on, and perhaps stain the adjacent surface. To prevent permanent staining, the adjacent surface should be made of a material that is heat resisting and easy to clean. Adjacent tall cabinets should not be deeper than the oven housing cabinet.

Important

It is essential that the lower cupboard is constructed in the manner illustrated i.e. having side, back and roof panels so joined as to provide no apertures which could permit access to the oven unit when installed.

3. Electrical Installation

Mains Supply

A 20 amp Double Pole control switch with a minimum contact clearance of 3mm must be fitted on or recessed in the wall adjacent to the oven housing cabinetry and should be accessible after installation. If the oven is to be wired into a connector unit this may be positioned behind the oven providing:–

i.The top of the connector unit is not more than 30cm above the base of the oven recess – see Fig. 4.

ii.The depth of the connector unit does not reduce the depth of the oven recess to less than 55cm.

We recommend that 4mm2 twin and earth PVC insulated cable is used to connect the cooker to the control unit. This power supply cable must conform to BS 6004.

Alternatively the mains supply can be taken from a household 13 amp switched fused spur. Having a minimum contact clearance of 3mm which must be fitted adjacent to the oven housing cabinetry and accessible after installation. The oven must be fitted with a 3 core cable having a minimum cross sectional area of 1.5mm2 and must conform to BS6500.

The oven must not be connected using a 3 pin 13 amp plug.

31

Image 31
Contents E010E / R010E Installation & User Instructions Creda Answer Centre 08701 54 64 Creda Answer Centre 08701 54 64Contents Disposal of your product IntroductionSafety Advice Safety InformationAlways Safety Information Never Features Control markings ControlsOven Timer Operation Clockface Know Your TimerSymbols Timer Function ButtonsSetting the Minute Minder Setting the Time of DAYAuto Cooking Programmes Electronic Clock and Automatic Oven Timer Operation Other Notes on Timer Operation Solarplus Grill Grill Pan Food Grid and Anti-Splash Tray Grill Pan and HandleStep Door Position for Grilling Grilling ProcedureFood Grill ChartOven shelf positioning for fan oven Using the Oven for Fan CookingTemperature and time Easy Glide ShelfFan oven operation Using the Oven for other Functions Conventional Fan Temperature Conversion ChartOven If Using Aluminium Foil Oven Temperature Chart MeatBaking Fan Oven Cooking Oven Temperature Chart BakingGrill Cooking Results Not SatisfactoryBaking General Cleaning Care and CleaningCredaclean Oven Liners E010E How Credaclean worksSolarplus Grill Cleaning the OvenBase of Main Oven Meat b Grill/Meat Pan & Oven ShelvesHOW to Clean the Lamp Lens Replacement of the Oven LampControl Panel / Trims / Inner Door Panel & Glass Remove the door inner glass as follows Cleaning the DoorsRefit the door inner glass as follows General Installation InstructionsElectrical Installation Oven Unit Housing CabinetsMains Supply All cases adhere to routing details see fig Final InstallationConduit Box to Mains Terminal Block List of Loose Items560mm 550mm Something Wrong? Problem CheckKey Contacts

E010E, R010E specifications

The Creda R010E and E010E are advanced electric heating solutions designed to provide efficient warmth and convenience for homes and commercial spaces. These units stand out due to their modern design, user-friendly features, and energy-saving technologies, making them ideal choices for individuals looking to optimize their indoor climate.

One of the main features of the Creda R010E and E010E is the advanced heating element, which ensures rapid warmth while maintaining low energy consumption. This efficiency is largely due to the incorporation of ceramic technology, which allows the units to store heat and release it gradually even after they have been turned off. This feature not only enhances comfort but also reduces energy bills, making them economically viable choices over traditional heating methods.

Both models are equipped with a precise electronic thermostat that ensures consistent and accurate temperature control. Users can easily set their desired comfort levels, and the heating units will intelligently adjust their output to maintain those temperatures. This sophisticated temperature management is complemented by programmable timers, enabling users to schedule heating times according to their needs, ensuring warmth is available when needed while avoiding unnecessary energy use.

The design of the Creda R010E and E010E reflects modern aesthetics, featuring sleek lines and a compact profile that allows for flexible placement in various settings. The lightweight construction means they can be easily mounted on walls, freeing up floor space while integrating seamlessly into any room’s décor.

Safety is also a critical consideration in the design of these units. Both models come with built-in overheat protection, ensuring that the heaters automatically switch off if they reach unsafe temperatures. Additionally, the sturdy build quality and high-grade materials enhance their durability, ensuring reliable performance over years of use.

Finally, the Creda R010E and E010E are also easy to maintain, with features designed to minimize dust and dirt buildup. Users can easily clean the external surfaces, ensuring optimal hygiene and a healthy living environment. With these technologies and characteristics, the Creda R010E and E010E represent some of the leading options for electric heating solutions in today's market, combining efficiency, safety, and modern aesthetics.