Whirlpool KSRJ25FXBL, MSD2559XEW, MSD2559XEM, MSD2559XEB, KSRJ25FXMS, KSRJ25FXMT SW1 SW2 SW3 SW4 SW5

Page 35

Service Diagnostics Mode (continued)

NOTE: This is an example of the information on the Technical Data Sheet shipped with the refrigerator.

 

 

Switch Diagram

 

 

SW1

SW2

SW3

SW4

SW5

SW6

Press SW5 to advance to the next step in sequence.

Press SW4 to return to the previous step.

Digit 1 Digit 2

Display Digits

Step

Amber LED's

Status

Red LED's

Step

Component

Suggested Diagnostics Routine

Component Status Indicator

Number

Tested

Cooling system steps 1-7

 

 

 

 

 

Dispensing system steps 8-30

 

 

 

3

Evaporator fan motor

Verify air flow from evaporator fan. Check to see if

01=Fan On, Air Baffle open

and air baffle motor

the air baffle opens and closes

02=Fan On, Air Baffle closed

 

 

 

 

4

Compressor and

Line voltage switched to compressor and condenser

 

01=ON

 

Condenser Fan Motor

fan from control board

 

02=OFF

 

 

 

 

 

 

 

5

Does Not Apply

This step is automatically by-passed

 

Does Not Apply

 

Defrost heater

Line voltage switched to components from board,

Blank= Waiting for validation

6

verify heater operation. If Bimetal is open, it will need

01= Bimetal Closed

 

and Bimetal

 

 

to be by-passed for heater to operate.

02=Bimetal Open

 

 

 

 

 

 

 

 

 

 

 

 

 

The Defrost Mode can be activated by using SW3. In

 

 

 

 

 

the ADC Mode the refrigerator will automatically

 

 

 

 

 

defrost after a minimum of 8 hours of compressor run

 

 

 

 

 

time and up to maximum of 96 hours of compressor

 

01=ADC ON

 

 

 

run time, depending upon product usage. In Basic

 

 

7

Defrost Mode

02= Basic Mode ON - 8 hour Timer

Mode the product will automatically defrost after 8

 

 

hours of compressor runtime. The Defrost Mode must

 

 

 

 

 

be set to ADC ON before exiting the Service

 

 

 

 

 

Diagnostic Mode. Press SW5 to indicate the

 

 

 

 

 

completion of this step and to continue with the

 

 

 

 

 

dispenser service routine.

 

 

 

 

Important: If Bi-Metal is by-passed for testing. Do Not Overheat the Evaporator Area

 

 

 

Dispensing System Steps 8-30

 

 

 

 

 

 

 

 

 

 

8

All UI indicators

Verify that all LED indicators and UI digits turn on

 

All indicators ON

automatically

 

 

 

 

 

 

 

 

 

 

Digit 1

Digit 2

SW Pressed

 

 

 

 

1

Blank

SW 1

 

 

Displays the User Interface Buttons and Ice and

2

Blank

SW 2

 

 

Water Pads status as described in the Component

3

Blank

SW 3

9

UI Button/Pad Test

Status Indicator column.

6

Blank

SW 6

 

 

Note: Do not use SW4 and SW5 as these are used

 

 

Blank

1

Ice Pad

 

 

only to navigate through the Service Diagnostics.

 

 

 

 

Blank

2

Water Pad

 

 

 

 

Blank

3

Ice

 

 

 

 

and Water

10

Does Not Apply

This step is automatically by-passed

 

Does Not Apply

11

Dispenser Lighting

Pressing SW3 will change the dispenser light setting

 

Blank

 

from OFF(0%) to ON(100%) to DIM(50%)

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Does Not Apply

This step is automatically by-passed

 

Does Not Apply

13

Dispenser Housing

Displays the Dispenser Housing Heater status on the

 

01=ON

 

Heater Status

UI display. Press SW3 to change status.

 

02=OFF

 

 

 

 

14

Does Not Apply

This step is automatically by-passed

 

Does Not Apply

15

Does Not Apply

This step is automatically by-passed

 

 

Does Not Apply

*Always refer to Service Sheet and Use and Care Manual for information specific to the refrigerator you are servicing.

32

Image 35
Contents March UD-39 KitchenAid and Maytag 25 SXS Refrigerators ModelsForward Table of Contents Model Number Description Kitchenaid and Maytag 25’ SXS RefrigeratorsUser Interface Blue and Amber Flush Dispenser with Stealth SoftwareAttaching or Removing Handles Removing Freezer Door Removing Freezer Door Connecting Water Line Machine Compartment New Ice Bin Release Freezer Compartment -FCAuger motor coupling lifts off motor Auger Motor CouplingRemoving Auger Motor Victoria Flush Mount DispenserRemoving User Interface Removing Dispenser Assembly Removing Dispenser Switches Wardangering Control AssemblyControl and Power Supply Boards Control Assembly Control Assembly Kitchenaid Stealth Control Overview Programming Instructions Sleep Mode Factory Preset Temperatures Adjusting Temperature Set Points Freezer Temperature Setting Adjusting Temperature SettingsMax Ice Ice DispenserDispenser Light Details Door Open AlarmDoor Open Icon Dispenser Lock Cooling On Mode Cooling Off Mode Water Filter Status Light Exiting the Showroom Mode Showroom ModeSwitch Diagram Service Diagnostics ModeSW1 SW2 SW3 SW4 SW5 Service Diagnostics Mode Service Sheet Service Sheet Wiring Diagram Wiring Diagram Wiring Diagram