Broan EW5630SS, EW5636SS manual Operation, Off, Filter Change Indication, Heat Sentry System, Fuses

Page 7

MODELS EW5630SS • EW5636SS

NON-DUCT 6” ROUND PLENUM FLEXIBLE

METAL DUCT DUCT LENGTH

DECORATIVE

FLUE

14.Measure and install section of flexible metal ductwork (included with RKE56) to hood duct connector and bottom of non-duct plenum. Use duct tape to make all joints secure and air tight.

CAUTION

Do not use plastic duct.

15.Plug power cord into wall outlet.

16.Slide the upper decorative flue section into the lower decorative flue section. NOTE For non-ducted applications, the upper flue should be oriented so the louvers are towards the ceiling.

17.Carefully place the upper/lower flue assembly into the recessed area of the hood.

18.Slide the upper flue upward until it is aligned with the non- duct plenum. The non-duct plenum should be inside the flue. Secure the upper flue to the non-duct plenum using (2) 4mm x 12mm mounting screws.

NOTE

9-10 ft. ceilings may require Flue Extension Model FXNE56SS depending on installation height (purchase separately). Discard the upper and lower flues supplied with your hood and replace them with Flue Extension Model FXNE56SS.

Page 7

OPERATION

Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.

Operate the hood as follows:

DELAY

 

OFF FAN

OFF LIGHT

 

FAN SPEED

OFF

LED INDICATORS

 

Turns the fan OFF

 

FAN (1-Pushbutton Switch, 3-Fan Speeds)

Turns the fan ON to the last selected speed, and activates a blue LED indicating the fan speed setting. Pressing the FAN button a second time will index the fan speed and LED indicator to the next highest setting. Pressing the FAN button when the fan is at the highest speed setting will index the fan and LED indicator to the lowest setting.

DELAY-OFF (10 Minute Delay-OFF)

Activates the 10 minute delay off feature when the fan is ON (any speed). When activated, the blue LED indicator above the selected speed setting will blink. The hood fan will automatically turn OFF after 10 minutes has elapsed. The DELAY-OFF button can be pressed at any time during the 10 minute countdown to turn off the feature.

LIGHT (1-Pushbutton Switch, 3-Light Intensities)

Turns the lights ON to the lowest intensity. Pressing the LIGHT button a second time will index the light intensity to the next highest level. Pressing the LIGHT button when the lights are at the highest intensity will turn the lights off.

FILTER CHANGE INDICATION

After 30 hours of fan operation, the three blue LED indicators will blink simultaneously, indicating that it is time to clean the grease filters. To reset the filter clean timer, press and hold the OFF button for 3 seconds. The blinking LED indicators will turn off.

HEAT SENTRY SYSTEM

This range hood is equipped with a standard Heat Sentry system that monitors excessive temperature and automatically turns the fan speed on HIGH.

1)If the fan is ON, the Heat Sentry system will increase the fan setting to its highest speed when the temperature is elevated. The blue indicator for fan speed (3) will illuminate and blink at a high rate, indicating that the heat sentry function is activated. Once the temperature has reduced, the Heat Sentry system will change the fan speed to the original setting.

2)If the fan is OFF, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. The blue indicator for fan speed (3) will illuminate and blink at a high rate, indicating that the heat sentry function is activated. After the temperature has lowered to normal, the fan will turn off.

FUSES

The Range Hood Control Board contains a Main Fuse to protect the controls from power surges. New fuses can be purchased at a local electronic supply store. Use 5A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-type fuses.

Image 7
Contents To Reduce the Risk of a Range TOP Grease Fire Read and Save These InstructionsInstall the Ductwork Ducted Hoods Only Measure the InstallationPrepare the Hood See Chart Below High Cooktop Install the Wiring Install the Hood Mounting SupportHere Install the Hood Ducted Hoods Only NON-DUCT KIT Model RKE56 Contents Install the Hood Non-Ducted Hoods OnlyModels EW5630SS EW5636SS Heat Sentry System OperationOFF Filter Change IndicationLight Bulbs Cleaning & MaintenanceRemote Control MAKE-UP AIR DamperWarranty Service PartsKEY Description QTY Lire CES Directives ET LES Conserver Installation DES Conduits hottes avec conduits seulement Mesures DE L’INSTALLATIONPréparation DE LA Hotte MAX Instructions DE Mise À LA TerreInstallation DE LA Hotte hottes avec conduits seulement Longueur DU Conduit Décoratif Installation DE LA Hotte hotte sans conduits seulementModèles EW5630SS EW5636SS Fonctionnement Ampoules Nettoyage ET EntretienGarantie Pièces DE RechangeDE Pièce Description QTÉ Repère LEA Y Conserve Estas Instrucciones Sólo en campanas con conductos Mida LA InstalaciónPrepare LA Campana Instale LOS ConductosInstrucciones Para LA Puesta a Tierra NotaInstalación Nivel con El cielo raso Instale LA CampanaContenido DEL KIT Para Sistemas SIN Conductos Modelo RKE56 Página Funcionamiento Bombillas Limpieza Y MantenimientoClave GarantíaDescripción Cdad Models / Modèles / Modelos EW5630SS EW5636SS