MODELS EW5630SS • EW5636SS
To replace a fuse (by qualified person(s):
1.Disconnect power at service entrance.
2.Remove decorative flues.
3.Remove control cover.
4.Remove and inspect fuse.
MAKE-UP AIR DAMPER
The hood is compatible with Broan
MAKE UP DAMPER CONNECTION | ||
| (switched low voltage) | |
| 20 GAUGE BELL WIRE FOR LOW | |
| VOLTAGE CONNECTION ON | |
| TOP OF HOOD |
|
24V |
|
|
TRANSFORMER | DRY CONTACT | |
(INCLUDED) |
| |
| TERMINAL | |
|
| |
GRD | HOOD | BUSHING |
|
| FOR LOW |
120 VAC |
| VOLTAGE |
60 HZ |
| CONNECTION |
Make the connection to the
REMOTE CONTROL
The hood is compatible with Broan Radio Frequency (RF) Remote Control Model BCR1 (optional). Purchase separately.
To link the BCR1 remote control with the hood, press and hold the LIGH T button for
The blue LED indicators will turn on and off in succession to indicate the hood is in RF linking mode. When in the linking mode, press any key on the RF remote. An audible beep will be heard at the hood, and the hood LED’s will stop blinking if a successful link is accomplished. If the remote control did not successfully link with the hood, the linking mode will be deactivated after 12 seconds, and the LED’s will stop the sequential blinking. Refer to the BCR1 instructions for additional information.
CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter, fan and
Clean
Clean the
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the blower assembly with an exact service replacement.
Page 8
LIGHT BULBS
| SUCTION |
| CUP TOOL |
HALOGEN | (1) |
PUSH IN | |
BULB |
|
(2) |
|
ROTATE |
|
CLOCKWISE |
|
WARNING
Bulbs may be hot. Always allow bulbs to cool down before removing them.
Use (2) Halogen Bulbs (included with hood) - 120 V, 35 W, shielded halogen bulbs - MR16 with GU10 base.
NOTE
Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated. The position of the bulb socket (depth) is adjustable and may require adjustment when: a) certain brands of bulbs are difficult to install. b) the bulb protrudes too far below the light panel.
LAMP SOCKET
BRACKET
LIGHT | SCREWS |
PANEL |
To change the depth of bulb sockets:
-Remove 2 screws on light panel – set screws aside
-Remove Light Panel.
-Loosen 2 Screws holding Lamp Socket Bracket to Light Panel.
-Adjust socket/bracket to desired depth.
-
-