19. LIGHT BULBS

This insert uses 50 W halogen lamps (120 V, 50 W, PAR 20) (Purchase separately). Install the lamps by rotating them clockwise into their socket holder.

20. INSTALL FILTERS

It is recommended to install side filters first and finish with center one(s). 1.Insert upper end of filter into the insert (finger sized cup side).

2.Raise lower end of filter to position it into grease rail inside of hood and pull. 3.While pulling the filter, slide it under the inner retaining piece.

Replacement filters are available from your dealer. See inside label insert for size and part number.

1

2

3

HD0086

HD0031

1

 

1) Finger sized cup

Baffle Filters

Baffle filters are available as an option. To order them, refer to the table below to find the right filter kit number for your insert. To install them, refer to instruction sheet included with baffle filter kit.

KIT NO.

INSERT MODEL

RBFIP33

RMIP33

RBFIP45

RMIP45

 

 

HD0011

21. USE AND CARE

BAFFLE FILTER (TYPICAL)

Grease filters and impeller(s).

The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution. Grease filters and impeller(s) are dishwasher safe.

Remove greasse filters by pushing them towards the back of hood and rotating downward.

Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by the warranty.

Stainless steel cleaning: How to maintain its «BRIGHT LOOK»

Do:

Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.

Always clean in the direction of original polish lines.

Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.

You may also use a specialized household stainless steel cleaner.

Don’t:

Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.

Use any harsh or abrasive cleansers.

Allow dirt to accumulate.

Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface.

- 12 -

Image 12
Contents Models RMIP33 and RMIP45 To Reduce the Risk of a Range TOP Grease Fire RMIP33 and RMIP45 Insert System RMIP33 or RMIP45 InsertIN-LINE and Exterior Blowers Select Blower Option and Install Ductwork Prepare the InstallationInstall Backsplash Optional Custom Hood PreparationSuggested Custom Hood Internal Framework Install Custom Hood Liner Optional Install the Rmipwc Remote Control OptionalInstall Blower Interior or Exterior Blower CUT the Hole in Custom Hood BaseInstall the Deviator Interior Blower Install the Adapter Interior BlowerRemove the KNOCK-OUT Opening Interior Blower 14’’ Connect Wiring ALL Blowers Install the ROUGH-IN Plate ALL Blowers Install the Transition Interior Blower Install the Insert Install the Blower Interior BlowerDucting Connection ALL Blowers Install the Blower Interior Blower CONT’D Dual blower P8Install Filters Light BulbsUSE and Care Don’tUSE and Care CONT’D OperationONE Year Limited Warranty for Broan Elite Products Single Blower ROUGH-IN Plate Assembly Wire CoverSingle Blower Assembly Strain Relief for Blower Power CordDual Blower ROUGH-IN Plate Assembly Dual Blower AssemblyMotor 165W CCW Modèles RMIP33 ET RMIP45 Avertissement Afin DE Réduire LES Risques DE FEU DE CuisinièreModèles RMIP33 ET RMIP45 Système DE Module Module DE Hotte Encastrable RMIP33 ou RMIP45Encastrable RMIP33 ou RMIP45Préparer L’INSTALLATION Sélectionner L’OPTION Ventilateur ET Nstaller LES ConduitsInstaller LE Dosseret Optionnel Préparation DE L’ARMOIRE DE HotteCharpente DE L’ARMOIRE Suggérée Installer LE Revêtement D’ARMOIRE Optionnel Installer LA Commande Murale Rmipwc OptionnelleInstaller LE Ventilateur Extérieur OU Intérieur Découper LE Trou Dans LA Base DE L’ARMOIREInstaller LE Déviateur Ventilateur Intérieur Installer L’ Adaptateur Ventilateur IntérieurEnlever L’OUVERTURE Préamorcée Ventilateur Intérieur OuvertureInstaller LA Plaque Ventilateur Tous LES Ventilateurs Installer LA Transition Ventilateur IntérieurBranchements Électriques Tous LES Ventilateurs Installer LE Module Installer LE Ventilateur Ventilateur InterieurRaccordement DES Conduits Tous LES Ventilateurs Installer LE Ventilateur Ventilateur Interieur Suite Ventilateur double P8Installer LES Filtres Ampoules HalogènesEntretien FaireEntretien Suite FonctionnementGarantie Limitée DE UN AN DES Produits Broan Elite DE LA Description QTÉ Déflecteur D’AIRPlaque Ventilateur Simple Assemblée CACHE-FILSDE LA Description QTÉ RÉF Plaque Ventilateur Double AssembléeVentilateur Double Assemblé Moteur 165 W CCWModelos RMIP33 Y RMIP45 Advertencia Modelos RMIP33 Y RMIP45 Sistema DE Dispositivo Dispositivo RMIP33 ó RMIP45Dispositivo RMIP33 ó RMIP45Seleccione LA Opción Ventilador Y Instale LOS Conductos Prepare LA InstalaciónInstale LA Placa Antisalpicaduras Opcional Preparación DE LA Campana ExtractoraArmazón Interno Recomendado Para LA Campana Extractora Instalación DEL Control Remoto Rmipwc Opcional Corte EL Orificio EN LA Base DE LA Campana ExtractoraInstale EL Ventilador Exterior Ó Interior Revestimiento Dispositivo Campana ExtractoraRompa LA Abertura Ventilador Interior Instale EL Desviador Ventilador InteriorInstale EL Adaptador Ventilador Interior Pieza Desmontable 14’’Conexión Eléctrica Todos LOS Ventiladores Instale LA Bandeja DE Conexion Todos LOS VentiladoresInstale LA Transición Ventilador Interior Conexión DEL Conducto Todos LOS Ventiladores Instalación DEL DispositivoInstalación DEL Ventilador Interior Instalación DEL Ventilador Interior Continuación Ventilador doble P8Luces Halógenas Instalación DE LOS FiltrosMantenimiento Debe hacerseMantenimiento Continuación FuncionamientoVentilador Lámparas HalógenasGarantía Limitada DE UN AÑO DE LOS Productos Broan Elite Pieza Descripción CTD Deflertor DE AireMontaje DE Placa DE Ventilador Simple CUBRE-CABLEMontaje DE Placa DE Ventilador Doble Montaje DE Ventilador DobleMotor 165 W CCW