Broan RMIP33 installation instructions To Reduce the Risk of a Range TOP Grease Fire

Page 2

!WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any solid-state speed control device other than RMIPWC optional wall mounted control.

8.

To reduce the risk of fire, use only metal ductwork.

9.This unit must be grounded.

10.When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when cooking flaming foods.

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

!WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN – You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion.

4.Use an extinguisher ONLY if:

A.You own a Class ABC extinguisher and you know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department has been called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1.For indoor use only

2.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

3.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4.Your insert motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the insert serviced.

5.The minimum hood distance above cooktop must not be less than 24”. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.

6.Two installers are recommended because of the large size and weight of this unit.

7.To reduce the risk of fire and to properly exhaust air, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.

8.This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.

9.Because of the high exhausting capacity of this unit, you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen.

10.To reduce the risk of fire and electrical shock, the Broan Elite models RMIP33 and RMIP45 must be installed only with Broan interior blower models P5 or P8; Broan exterior models 331H, 332H, 335 or 336; Broan in-line blowers models HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Blowers sold separately).

11.Use with approved cord-connection kit only.

12.Please read specification label on product for further information and requirements.

- 2 -

Image 2
Contents Models RMIP33 and RMIP45 To Reduce the Risk of a Range TOP Grease Fire RMIP33 and RMIP45 Insert System RMIP33 or RMIP45 InsertIN-LINE and Exterior Blowers Select Blower Option and Install Ductwork Prepare the InstallationSuggested Custom Hood Internal Framework Install Backsplash OptionalCustom Hood Preparation Install Blower Interior or Exterior Blower Install Custom Hood Liner OptionalInstall the Rmipwc Remote Control Optional CUT the Hole in Custom Hood BaseRemove the KNOCK-OUT Opening Interior Blower Install the Deviator Interior BlowerInstall the Adapter Interior Blower 14’’Install the Transition Interior Blower Connect Wiring ALL BlowersInstall the ROUGH-IN Plate ALL Blowers Ducting Connection ALL Blowers Install the InsertInstall the Blower Interior Blower Install the Blower Interior Blower CONT’D Dual blower P8USE and Care Install FiltersLight Bulbs Don’tUSE and Care CONT’D OperationONE Year Limited Warranty for Broan Elite Products Single Blower Assembly Single Blower ROUGH-IN Plate AssemblyWire Cover Strain Relief for Blower Power CordMotor 165W CCW Dual Blower ROUGH-IN Plate AssemblyDual Blower Assembly Modèles RMIP33 ET RMIP45 Avertissement Afin DE Réduire LES Risques DE FEU DE CuisinièreModèles RMIP33 ET RMIP45 Système DE Module Module DE Hotte Encastrable RMIP33 ou RMIP45Encastrable RMIP33 ou RMIP45Préparer L’INSTALLATION Sélectionner L’OPTION Ventilateur ET Nstaller LES ConduitsCharpente DE L’ARMOIRE Suggérée Installer LE Dosseret OptionnelPréparation DE L’ARMOIRE DE Hotte Installer LE Ventilateur Extérieur OU Intérieur Installer LE Revêtement D’ARMOIRE OptionnelInstaller LA Commande Murale Rmipwc Optionnelle Découper LE Trou Dans LA Base DE L’ARMOIREEnlever L’OUVERTURE Préamorcée Ventilateur Intérieur Installer LE Déviateur Ventilateur IntérieurInstaller L’ Adaptateur Ventilateur Intérieur OuvertureBranchements Électriques Tous LES Ventilateurs Installer LA Plaque Ventilateur Tous LES VentilateursInstaller LA Transition Ventilateur Intérieur Raccordement DES Conduits Tous LES Ventilateurs Installer LE ModuleInstaller LE Ventilateur Ventilateur Interieur Installer LE Ventilateur Ventilateur Interieur Suite Ventilateur double P8Entretien Installer LES FiltresAmpoules Halogènes FaireEntretien Suite FonctionnementGarantie Limitée DE UN AN DES Produits Broan Elite Plaque Ventilateur Simple Assemblée DE LA Description QTÉDéflecteur D’AIR CACHE-FILSVentilateur Double Assemblé DE LA Description QTÉ RÉFPlaque Ventilateur Double Assemblée Moteur 165 W CCWModelos RMIP33 Y RMIP45 Advertencia Modelos RMIP33 Y RMIP45 Sistema DE Dispositivo Dispositivo RMIP33 ó RMIP45Dispositivo RMIP33 ó RMIP45Seleccione LA Opción Ventilador Y Instale LOS Conductos Prepare LA InstalaciónArmazón Interno Recomendado Para LA Campana Extractora Instale LA Placa Antisalpicaduras OpcionalPreparación DE LA Campana Extractora Instale EL Ventilador Exterior Ó Interior Instalación DEL Control Remoto Rmipwc OpcionalCorte EL Orificio EN LA Base DE LA Campana Extractora Revestimiento Dispositivo Campana ExtractoraInstale EL Adaptador Ventilador Interior Rompa LA Abertura Ventilador InteriorInstale EL Desviador Ventilador Interior Pieza Desmontable 14’’Instale LA Transición Ventilador Interior Conexión Eléctrica Todos LOS VentiladoresInstale LA Bandeja DE Conexion Todos LOS Ventiladores Instalación DEL Ventilador Interior Conexión DEL Conducto Todos LOS VentiladoresInstalación DEL Dispositivo Instalación DEL Ventilador Interior Continuación Ventilador doble P8Mantenimiento Luces HalógenasInstalación DE LOS Filtros Debe hacerseVentilador Mantenimiento ContinuaciónFuncionamiento Lámparas HalógenasGarantía Limitada DE UN AÑO DE LOS Productos Broan Elite Montaje DE Placa DE Ventilador Simple Pieza Descripción CTDDeflertor DE Aire CUBRE-CABLEMotor 165 W CCW Montaje DE Placa DE Ventilador DobleMontaje DE Ventilador Doble