Broan RMIP33 Install Custom Hood Liner Optional, Install the Rmipwc Remote Control Optional

Page 7

6. INSTALL CUSTOM HOOD LINER (OPTIONAL)

The liners are specially designed to protect the exterior base of the custom hood. To order, refer to the table below to find the right liner model number for your insert and width of custom hood. To view specific model information, including depths for each liner models, visit www.broan.com or contact Technical Support (phone number listed on front cover). To install, see instruction packed with custom hood liner.

The liner must be installed before the insert.

NOTE : On some liners models, front liner piece may overlap front insert flange. If so, remove the front liner piece, assemble insert, and reassemble front liner piece.

 

LINER MODEL

INSERT MODEL

CUSTOM HOOD

 

 

 

NOMINAL WIDTH

 

 

RML3336S

RMIP33

36’’

 

 

RML3342S

RMIP33

42’’

 

 

RML4548S

RMIP45

48’’

 

 

RML4554S

RMIP45

54’’

 

 

RML4560S

RMIP45

60’’

 

 

 

 

 

HA0038A

7. INSTALL THE RMIPWC REMOTE CONTROL (OPTIONAL)

The electrical connection for the remote control is located in front of the insert. Perform this connection before the insert installation. For installation details, see installation instructions included with the RMIPWC remote control.

HL0044

8. CUT THE HOLE IN CUSTOM HOOD BASE

If it is not done yet, cut a hole in the bottom of the cabinet, using the dimensions shown beside.

INSERT MODEL NUMBER

A

 

RMIP33

32½’’

 

 

RMIP45

44½’’

NOTES : 1. The notch shown in the inset must be cut only if the RMIPWC optional remote control will be installed.

2.The recommended distance from the back to the rearmost cutout edge is 2¼’’ minimum.

 

3 1/2''

17 1/16''

16 3/8''

2 1/4''

A

min.

 

HD0084A

 

9. INSTALL BLOWER (INTERIOR OR EXTERIOR BLOWER)

INTERIOR BLOWER: Follow all subsequent steps of this manual.

EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 13, 14, 16, 17, 19 and up of this manual.

- 7 -

Image 7
Contents Models RMIP33 and RMIP45 To Reduce the Risk of a Range TOP Grease Fire RMIP33 or RMIP45 Insert RMIP33 and RMIP45 Insert SystemIN-LINE and Exterior Blowers Prepare the Installation Select Blower Option and Install DuctworkCustom Hood Preparation Install Backsplash OptionalSuggested Custom Hood Internal Framework CUT the Hole in Custom Hood Base Install Custom Hood Liner OptionalInstall the Rmipwc Remote Control Optional Install Blower Interior or Exterior Blower14’’ Install the Deviator Interior BlowerInstall the Adapter Interior Blower Remove the KNOCK-OUT Opening Interior BlowerInstall the ROUGH-IN Plate ALL Blowers Connect Wiring ALL BlowersInstall the Transition Interior Blower Install the Blower Interior Blower Install the InsertDucting Connection ALL Blowers Dual blower P8 Install the Blower Interior Blower CONT’DDon’t Install FiltersLight Bulbs USE and CareOperation USE and Care CONT’DONE Year Limited Warranty for Broan Elite Products Strain Relief for Blower Power Cord Single Blower ROUGH-IN Plate AssemblyWire Cover Single Blower AssemblyDual Blower Assembly Dual Blower ROUGH-IN Plate AssemblyMotor 165W CCW Modèles RMIP33 ET RMIP45 Afin DE Réduire LES Risques DE FEU DE Cuisinière AvertissementModule DE Hotte Encastrable RMIP33 ou RMIP45 Modèles RMIP33 ET RMIP45 Système DE ModuleRMIP33 ou RMIP45 EncastrableSélectionner L’OPTION Ventilateur ET Nstaller LES Conduits Préparer L’INSTALLATIONPréparation DE L’ARMOIRE DE Hotte Installer LE Dosseret OptionnelCharpente DE L’ARMOIRE Suggérée Découper LE Trou Dans LA Base DE L’ARMOIRE Installer LE Revêtement D’ARMOIRE OptionnelInstaller LA Commande Murale Rmipwc Optionnelle Installer LE Ventilateur Extérieur OU IntérieurOuverture Installer LE Déviateur Ventilateur IntérieurInstaller L’ Adaptateur Ventilateur Intérieur Enlever L’OUVERTURE Préamorcée Ventilateur IntérieurInstaller LA Transition Ventilateur Intérieur Installer LA Plaque Ventilateur Tous LES VentilateursBranchements Électriques Tous LES Ventilateurs Installer LE Ventilateur Ventilateur Interieur Installer LE ModuleRaccordement DES Conduits Tous LES Ventilateurs Ventilateur double P8 Installer LE Ventilateur Ventilateur Interieur SuiteFaire Installer LES FiltresAmpoules Halogènes EntretienFonctionnement Entretien SuiteGarantie Limitée DE UN AN DES Produits Broan Elite CACHE-FILS DE LA Description QTÉDéflecteur D’AIR Plaque Ventilateur Simple AssembléeMoteur 165 W CCW DE LA Description QTÉ RÉFPlaque Ventilateur Double Assemblée Ventilateur Double AssembléModelos RMIP33 Y RMIP45 Advertencia Dispositivo RMIP33 ó RMIP45 Modelos RMIP33 Y RMIP45 Sistema DE DispositivoRMIP33 ó RMIP45 DispositivoPrepare LA Instalación Seleccione LA Opción Ventilador Y Instale LOS ConductosPreparación DE LA Campana Extractora Instale LA Placa Antisalpicaduras OpcionalArmazón Interno Recomendado Para LA Campana Extractora Revestimiento Dispositivo Campana Extractora Instalación DEL Control Remoto Rmipwc OpcionalCorte EL Orificio EN LA Base DE LA Campana Extractora Instale EL Ventilador Exterior Ó InteriorPieza Desmontable 14’’ Rompa LA Abertura Ventilador InteriorInstale EL Desviador Ventilador Interior Instale EL Adaptador Ventilador InteriorInstale LA Bandeja DE Conexion Todos LOS Ventiladores Conexión Eléctrica Todos LOS VentiladoresInstale LA Transición Ventilador Interior Instalación DEL Dispositivo Conexión DEL Conducto Todos LOS VentiladoresInstalación DEL Ventilador Interior Ventilador doble P8 Instalación DEL Ventilador Interior ContinuaciónDebe hacerse Luces HalógenasInstalación DE LOS Filtros MantenimientoLámparas Halógenas Mantenimiento ContinuaciónFuncionamiento VentiladorGarantía Limitada DE UN AÑO DE LOS Productos Broan Elite CUBRE-CABLE Pieza Descripción CTDDeflertor DE Aire Montaje DE Placa DE Ventilador SimpleMontaje DE Ventilador Doble Montaje DE Placa DE Ventilador DobleMotor 165 W CCW