Cannon Installation Instructions, Model Numbers C60GC, C60GT, Location

Page 28

INSTALLATION INSTRUCTIONS

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the back panel.

This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. particular attention should be given to the relevant requirements regarding ventilation.

MODEL NUMBERS C60GC, C60GT

Category II2H3+ (GB)

These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30) at 28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit supplied with the cooker.

GAS SAFETY (INSTALLATION & USE) REGULATIONS

It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law.

In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172.

Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution.

LOCATION

The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3.

When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal space below ground level, e.g. in a basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.

The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.

28

Image 28
Contents Chesterfield Traditional Contents Introduction For Your Safety AlwaysFor Your Safety Automatic Cooking Oven Timer OperationGuidance on Automatic Cooking Clockface Setting the Time of DAY Auto Cooking Programmes Oven Timer Operation Other Notes on Timer Operation Hotplate To USE the HotplateSafety Requirements for Deep FAT Frying HOW to Deal with a FAT FireStandard Grill PAN and Handle Chesterfield GrillLarge Easyglide Grill PAN Traditional To USE the Grill Relighting the BurnerMain Oven To USE the Main OvenCold Start Cooking Roasting of Large PoultryStorage and RE-HEATING of Food ‘COOK CHILL’ DishesMain Oven Cooking Chart Meat and PoultryYeast Mixtures ‘SLOW COOK’ Setting Using the ‘SLOW COOK’ Setting for Slow CookingTOP Oven Guidance on Using the TOP OvenTo USE the TOP Oven TOP Oven Cooking Chart Gas Shelf Food Care and Cleaning Oven Heat Clean LiningsReplacement of Oven Light Bulb Oven DoorsCare and Cleaning Cooker Finish Cleaning MethodProblem Check Something Wrong With Your CookerSomething Wrong Installation Instructions GAS Safety Installation & USE RegulationsModel Numbers C60GC, C60GT LocationTechnical Data BurnerSpace for Fixing Cooker HoodsLevelling Unpacking the CookerConversion for USE on Butane G30 or Propane G31 Connecting to GAS Supply Stability ChainElectrical Connection Connect to a 230-240V A.C. Supply onlyInstallation and Operational Checks Page Key Contacts