Installation

Utility Connections

THE INSTALLATION INSTRUCTIONS CON- TAINED HEREIN ARE FOR THE USE OF QUALI- FIED INSTALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERATOR.

Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for:

Dthe installation of electrical wiring from the elec- tric meter, main control box or service outlet to the electric appliance.

Qualified installation personnel must be experi- enced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction.

U.S. and Canadian installations

All ovens, when installed, must be electrically

grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 ---Latest Edition and/or Cana- dian National Electric Code C22.2 as applicable.

The ventilation of this oven should be in accor- dance with local codes. In the absence of local

codes, refer to the National ventilation code titled, “Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equipment”, NFPA-96-Latest

Edition.

General export installations

Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local dis- tributor, please call the Blodgett Oven Company at 0011-802-860-3700.

ELECTRICAL CONNECTION

U.S and Canadian installations

This unit is supplied with a power cord and 6-20P NEMA plug (3 prong grounding 250 volt). It is in- tended for use with a 6-20R NEMA receptacle.

WARNING!!

This appliance is equipped with three prong grounding type plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. DO NOT cut or remove the grounding prong from this plug.

General export installations

Before making any utility connections to this oven, check the rating plate attached to the back of the oven to be sure the voltage, phase and KW rating are compatible with the electrical services sup- plied for the oven. See the table on page 2 for elec- trical specifications.

THE BLODGETT OVEN COMPANY CANNOT AS- SUME RESPONSIBILITY FOR LOSS OR DAMAGE SUFFERED AS A RESULT OF IMPROPER INSTAL- LATION.

7

Image 11
Contents KCO-25E For Your Safety Reputation YOU can Count on Page Table of Contents Introduction Oven Description and SpecificationsElectrical Specifications per section Volts Phase Amps Oven Components Oven Location InstallationDelivery and Location Delivery and InspectionOven Leveling Oven AssemblyLEG Attachment Double StackingDoor Relocation Electrical Connection Canadian installationsGeneral export installations Utility ConnectionsOperating Tips Safety Information and Operating TipsSafety Tips OperationDisplay Messages Solid State Digital ControlOven Controls To program a selected Product Key To enter the Program ModeOven Operation Product ProgrammingRecipe Temp Time To exit the Program ModePreset Programming Suggested Times and Temperatures Preventative Maintenance MaintenanceCleaning and Preventative Maintenance Cleaning the OvenPossible Causes Suggested Remedy Troubleshooting GuideCustomer Insert Wiring Diagram Here