Zephyr GU5/MR16 Display Options, Light Indicator, To enable Charcoal Filter Replacement Function

Page 10

www.zephyronline.com

5. Display Options

5.1LIGHT INDICATOR (5)

- Light indicator will turn on when lights are turned on at any light level

5.2FILTER CLEAN AND CHARCOAL FILTER REPLACE INDICATOR (6)

-METAL FILTER CLEAN (always enabled)

-Filter Clean Indicator will illuminate after 30 hours of fan usage indicating it is time to clean the metal filter. Indicator light will remain illuminated, it will not blink

-This function must be reset by the user. With hood off, hold the Fan Speed Button for five se- conds, after five seconds the Filer Clean Indicator will turn off and the 30 hour timer will reset

clean metal filter indicator becomes illuminated and fan on speed 3 (indicator turns on after 30 hours of fan usage)

-CHARCOAL FILTER REPLACE (disabled by default, must be enabled by user if recirculating hood)

-To enable Charcoal Filter Replacement Function:

With hood off, hold Fan Speed and Delay Off buttons simultaneously for 5 seconds.

Filter Clean Indicator will quickly flash 3 times indicating the Charcoal Filter Replacement Fun- ction is enabled.

-Filter Clean Indicator will continuously blink after 120 hours of unit fan usage indicating it is time to replace the charcoal filter. Indicator light will blink, it will not remain illuminated.

-This function must be reset by the user. With hood off, hold the Delay Off Button for five seconds, after five seconds the Filter Clean Indicator will stop blinking and turn off and the 120 hour timer will reset.

Order replacement charcoal filter kit number Z0F-00AC through your local dealer, www.zephyronline.com or the Zephyr customer service department.

-To disable Charcoal Filter Replacement Function:

With hood off, hold Fan Speed and Delay Off buttons simultaneously for 5 seconds.

Filter Clean Indicator will illuminate for 3 second then turn off indicating the Charcoal Filter Re- placement Function is disabled.

replace charcoal filter indicator blinking and fan on speed 3 (indicator turns on after 120 hours of fan usage)

- 10 -

Image 10
Contents User Guide Touch Glass Controls Page Page Contents Important Safety Instructions For Residential USE only SafetyPlease Read Entire Instructions Before Proceeding Installation Instructions Operation Remote ControlSynchronisation General InformationUser Interface Keypad Layout Display LayoutIndividual Button Functions Power ButtonDelay OFF Button FAN Speed ButtonTo enable Charcoal Filter Replacement Function Light IndicatorFilter Clean and Charcoal Filter Replace Indicator To disable Charcoal Filter Replacement FunctionTo enable Clean Air Function Delay OFF IndicatorClean AIR Indicator To disable Clean Air FunctionFAN Speed Indicator Maintenance Replacing the Light Bulb For bulb type G4 12V 20W hood models ADU, ADL, and AEDJUN08.0101 Sommaire Sécurité Commencer PAR Lire Entierement LES InstructionsInstructions D’INSTALLATION Sécurité Fonctionnement TélécommandeInformations Générales Configuration DES Commandes Configuration DE L’ÉCRAN Interface UtilisateurFonctions Des Touches Touche Power Allumage / ExtinctionTouche Delay OFF Extinction Différée Touche FAN Speed Vitesse TurbineAffichage Sur L’ecran Voyant DE Remplacement DU Filtre À CharbonVoyant Lumières Pour activer la fonction d’air propre Voyant D’EXTINCTION DifféréeVoyant D’AIR Propre Fonction AIR Propre Pour désactiver la fonction d’air propreVoyant Vitesse Turbine Mantenance Remplacement DE L’AMPOULE Índice Seguridad LEA LAS Instrucciones Completamente Antes DE ProcederInstrucciones Para LA Instalacion Seguridad Funcionamiento TelemandoSincronización Información GeneralInterfaz usuario Layout Botonera Layout DisplayFunciones De Cada Botón Botón Power Encendido / ApagadoBotón Delay OFF Apagado Retrasado Botón FAN Speed Velocidad DEL VentiladorPiloto DE Sustitución DEL Filtro DE Carbón Visualización En VisorPiloto DE Luces Para activar la función de sustitución del filtro de carbónPiloto DE Apagado Retrasado Piloto DE Aire Limpio Función DE Aire LimpioPiloto DE Velocidad DEL Ventilador Mantención MANTENCIóNSustitución DE LA Lámpara ¡ATENCIÓNIndice Leggere E Conservare LE Istruzioni Leggere Completamente LE Istruzioni Prima DI ProcedereIstruzioni PER L’INSTALLAZIONE SicurezzaSicurezza Telecomando Interfaccia Utente Layout Pulsantiera Layout DisplayFunzioni Del Singolo Tasto Tasto Power Accensione / SpegnimentoTasto Delay OFF Spegnimento Ritardato Tasto FAN Speed Velocità MotoreSpia Sostituzione Filtro Carbone Visualizzazioni Sul DisplayPer attivare la funzione di sostituzione del filtro carbone Per attivare la funzione aria pulita Spia DI Spegnimento RitardatoSpia Aria Pulita Funzione Aria Pulita Per disattivare la funzione aria pulitaSpia Velocità Motore Manutenzione Attenzione Sostituzione Della Lampada DicroicaPer lampadine tipo G4 12V 20W modelli cappe ADU, ADL e AED 3LIK0516

GU4/MR11, GU5/MR16 specifications

The Zephyr GU4/MR11 and GU5/MR16 LED lamps represent a significant advancement in lighting technology, catering to both residential and commercial applications. These compact and efficient lights are designed to fit into a variety of fixtures, providing quality illumination while minimizing energy consumption.

The GU4/MR11 lamp is characterized by its small size and low voltage, making it ideal for accent lighting and decorative applications. With a diameter of 35mm, it seamlessly fits into tight spaces and narrow fixtures. The GU5/MR16 lamp, on the other hand, has a diameter of 50mm and is more commonly used for general lighting and spotlighting. Both lamps come with a bi-pin base, allowing for easy installation and replacement in compatible fixtures.

One of the key features of the Zephyr series is its high energy efficiency. These LED lamps consume significantly less power compared to traditional halogen counterparts, leading to reduced electricity bills and a smaller carbon footprint. Additionally, they have a long lifespan, often lasting up to 25,000 hours or more, which reduces the frequency of replacements and contributes to less waste.

In terms of light output, the Zephyr GU4/MR11 and GU5/MR16 lamps offer a range of color temperatures, from warm white (around 2700K) to daylight (upwards of 5000K). This versatility allows users to choose the right ambiance for any setting, whether it’s a cozy living room or a vibrant retail environment. The high Color Rendering Index (CRI) of these lamps ensures that colors appear true and vibrant, enhancing the visual quality of spaces.

Advanced thermal management technology is also a hallmark of the Zephyr series. Their design includes heat sinks that dissipate heat efficiently, which not only improves performance but also extends the lifespan of the LEDs. This is critical for maintaining consistent light output and avoiding the flickering commonly associated with inferior products.

Furthermore, these lamps are compatible with various dimming systems, providing users with greater control over their lighting environment. They seamlessly integrate into smart home systems, allowing for remote control and scheduling, thereby enhancing convenience and energy savings.

In conclusion, the Zephyr GU4/MR11 and GU5/MR16 LED lamps combine innovation and functionality, making them an excellent choice for modern lighting solutions. With their energy efficiency, long lifespan, customizable lighting options, and advanced thermal management, these lamps stand out in the market, setting a high standard for quality and performance in LED lighting.