Zephyr GU4/MR11, GU5/MR16 manual Important Safety Instructions For Residential USE only

Page 5

IMPORTANT SAFETY INSTRUCTIONS

FOR RESIDENTIAL USE ONLY

READ AND SAVE THESE INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

Take care when using cleaning agents or detergents.

Suitable for use in household cooking area

WARNING - To reduce the risk of fire or electric shock, do not use this fan with any Solid-State Speed Control Device.

CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

CAUTION - For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

CAUTION - Please read specification label on product for further information and require- ments.

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE

THE FOLLOWING:

 

A. Use this unit only in the manner intended by the manufacturer. If you have ques

tions,

contact the manufacturer.

 

B. Before servicing or cleaning unit, switch power off at service panel and lock

the service

disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.Always turn hood ON when cooking at high heat or when flambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ).

C.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D.Use proper pan size. Always use cookware appropriate for the size of the surface element.

E.Keep fan, filters and grease laden surface clean.

F.Use high range setting on range only when necessary.Heat oil slowly on low to medium set- ting.

1. Safety

- 5 -

Image 5
Contents User Guide Touch Glass Controls Page Page Contents Please Read Entire Instructions Before Proceeding SafetyImportant Safety Instructions For Residential USE only Installation Instructions Synchronisation Remote ControlOperation General InformationKeypad Layout Display Layout User InterfaceDelay OFF Button Power ButtonIndividual Button Functions FAN Speed ButtonFilter Clean and Charcoal Filter Replace Indicator Light IndicatorTo enable Charcoal Filter Replacement Function To disable Charcoal Filter Replacement FunctionClean AIR Indicator Delay OFF IndicatorTo enable Clean Air Function To disable Clean Air FunctionFAN Speed Indicator Maintenance For bulb type G4 12V 20W hood models ADU, ADL, and AED Replacing the Light BulbJUN08.0101 Sommaire Commencer PAR Lire Entierement LES Instructions SécuritéInstructions D’INSTALLATION Sécurité Informations Générales TélécommandeFonctionnement Interface Utilisateur Configuration DES Commandes Configuration DE L’ÉCRANTouche Delay OFF Extinction Différée Touche Power Allumage / ExtinctionFonctions Des Touches Touche FAN Speed Vitesse TurbineVoyant Lumières Voyant DE Remplacement DU Filtre À CharbonAffichage Sur L’ecran Voyant D’AIR Propre Fonction AIR Propre Voyant D’EXTINCTION DifféréePour activer la fonction d’air propre Pour désactiver la fonction d’air propreVoyant Vitesse Turbine Mantenance Remplacement DE L’AMPOULE Índice LEA LAS Instrucciones Completamente Antes DE Proceder SeguridadInstrucciones Para LA Instalacion Seguridad Sincronización TelemandoFuncionamiento Información GeneralLayout Botonera Layout Display Interfaz usuarioBotón Delay OFF Apagado Retrasado Botón Power Encendido / ApagadoFunciones De Cada Botón Botón FAN Speed Velocidad DEL VentiladorPiloto DE Luces Visualización En VisorPiloto DE Sustitución DEL Filtro DE Carbón Para activar la función de sustitución del filtro de carbónPiloto DE Aire Limpio Función DE Aire Limpio Piloto DE Apagado RetrasadoPiloto DE Velocidad DEL Ventilador MANTENCIóN Mantención¡ATENCIÓN Sustitución DE LA LámparaIndice Leggere Completamente LE Istruzioni Prima DI Procedere Leggere E Conservare LE IstruzioniSicurezza Istruzioni PER L’INSTALLAZIONESicurezza Telecomando Layout Pulsantiera Layout Display Interfaccia UtenteTasto Delay OFF Spegnimento Ritardato Tasto Power Accensione / SpegnimentoFunzioni Del Singolo Tasto Tasto FAN Speed Velocità MotorePer attivare la funzione di sostituzione del filtro carbone Visualizzazioni Sul DisplaySpia Sostituzione Filtro Carbone Spia Aria Pulita Funzione Aria Pulita Spia DI Spegnimento RitardatoPer attivare la funzione aria pulita Per disattivare la funzione aria pulitaSpia Velocità Motore Manutenzione Per lampadine tipo G4 12V 20W modelli cappe ADU, ADL e AED Sostituzione Della Lampada DicroicaAttenzione 3LIK0516

GU4/MR11, GU5/MR16 specifications

The Zephyr GU4/MR11 and GU5/MR16 LED lamps represent a significant advancement in lighting technology, catering to both residential and commercial applications. These compact and efficient lights are designed to fit into a variety of fixtures, providing quality illumination while minimizing energy consumption.

The GU4/MR11 lamp is characterized by its small size and low voltage, making it ideal for accent lighting and decorative applications. With a diameter of 35mm, it seamlessly fits into tight spaces and narrow fixtures. The GU5/MR16 lamp, on the other hand, has a diameter of 50mm and is more commonly used for general lighting and spotlighting. Both lamps come with a bi-pin base, allowing for easy installation and replacement in compatible fixtures.

One of the key features of the Zephyr series is its high energy efficiency. These LED lamps consume significantly less power compared to traditional halogen counterparts, leading to reduced electricity bills and a smaller carbon footprint. Additionally, they have a long lifespan, often lasting up to 25,000 hours or more, which reduces the frequency of replacements and contributes to less waste.

In terms of light output, the Zephyr GU4/MR11 and GU5/MR16 lamps offer a range of color temperatures, from warm white (around 2700K) to daylight (upwards of 5000K). This versatility allows users to choose the right ambiance for any setting, whether it’s a cozy living room or a vibrant retail environment. The high Color Rendering Index (CRI) of these lamps ensures that colors appear true and vibrant, enhancing the visual quality of spaces.

Advanced thermal management technology is also a hallmark of the Zephyr series. Their design includes heat sinks that dissipate heat efficiently, which not only improves performance but also extends the lifespan of the LEDs. This is critical for maintaining consistent light output and avoiding the flickering commonly associated with inferior products.

Furthermore, these lamps are compatible with various dimming systems, providing users with greater control over their lighting environment. They seamlessly integrate into smart home systems, allowing for remote control and scheduling, thereby enhancing convenience and energy savings.

In conclusion, the Zephyr GU4/MR11 and GU5/MR16 LED lamps combine innovation and functionality, making them an excellent choice for modern lighting solutions. With their energy efficiency, long lifespan, customizable lighting options, and advanced thermal management, these lamps stand out in the market, setting a high standard for quality and performance in LED lighting.