Zephyr ESL-M90AS manual Hooks

Page 12

Installation

d. Fasten the hood to the motor unit using 6

 

 

screws from the bottom (release the grease

 

filter to access fixing points.

15.Hang hood with the 2 mounting hooks.

WARNING

Excessive Weight Hazard - Use two or more people to move and install range hood. Failure to do so can result in back or other injury.

16.Level the appliance, using a carpenters level across

bottom of hood with leveling screws in mounting hooks.

17.Secure hood with 1 screw on bottom.

Duct cover support bracket

Lower support bracket

Hooks

Hooks

bottom screw hole

Rear view

18.Connect ducting to transition. Seal with duct tape.

Do not use duct smaller than the transition.

For Ductless - recirculating - installations only: provide and install a duct to connect hood transition to deflector (the deflector is available as an extra kit).

12

Image 12
Contents JAN06.0101 Page Table of Contents Important safety Notice OperationElectrical & Installation requirements Before Installing the HoodElectrical Requirements List of Materials Parts SuppliedParts not Supplied Dimensions and clearances Installation Instructions Venting MethodsPreparation Installation Ductwork Calculation Sheet Installation Assembling the duct cover support bracket 3 partsInstallation Hooks Electrical connection Electrical Grounding InstructionsDuct cover support bracket Description of the hood Reset filter saturation signal Description of the hood Control BallControls Description of control ball and hood operationDescription of the hood Remote Control Using the Remote ControlRemote Control Maintenance Maintenance CleaningGrease Filter Replacing the Light BulbIssue Cause What to do ShootingWarranty To Obtain Service Under WarrantyList of Parts and Accessories GF02IAZRC-00SA