Zephyr ESL-M90AS manual Installation Ductwork Calculation Sheet

Page 9

www.zephyronline.com

Duct pieces

 

Equivalent number

 

 

 

lenght x used

=

Total

3

1/4 ” x 10”

1 Ft.

x (

) =

Ft.

Rect.,

 

 

 

 

straight

 

 

 

 

6

” Round,,

1 Ft.

x (

) =

Ft.

straight

 

 

 

 

7", 8”

1 Ft.

x (

) =

Ft.

Round,,

 

 

 

 

straight

 

 

 

 

3

1/4 ” x 10”

15 Ft.

x (

) =

Ft.

Rect.90°

 

 

 

 

elbow

 

 

 

 

3

1/4 ” x 10”

9 Ft.

x (

) =

Ft.

Rect.45°

 

 

 

 

elbow

 

 

 

 

3

1/4 ” x 10”

24 Ft.

x (

) =

Ft.

Rect.90°

 

 

 

 

flat elbow

 

 

 

 

3

1/4 ” x 10”

30 Ft.

x (

) =

Ft.

Rect.

 

 

 

 

wall cap

 

 

 

 

with damper

 

 

 

 

3

1/4 ” x 10”

5 Ft.

x (

) =

Ft.

Rect.to

 

 

 

 

6

” round

 

 

 

 

transition

 

 

 

 

3

1/4 ” x 10”

15 Ft.

x (

) =

Ft.

Rect.to

 

 

 

 

6

” round

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

6

” Round,,

15 Ft.

x (

) =

Ft.

90° elbow

 

 

 

 

6

” Round,,

9 Ft.

x (

) =

Ft.

45°elbow

 

 

 

 

 

 

Subtotal column 1 =

 

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.

Duct pieces

Equivalent number

 

 

lenght x used

=

Total

6" Round

30 Ft.

x (

) =

Ft.

wall cap

 

 

 

 

with damper

 

 

 

 

6” Round,

30 Ft.

x (

) =

Ft.

roof cap

 

 

 

 

6” Round to

1 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

6” Round to

16 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

7", 8" round

15 Ft.

x (

) =

Ft.

90° elbow

 

 

 

 

7", 8" round

9 Ft.

x (

) =

Ft.

45° elbow

 

 

 

 

7", 8" Round

30 Ft.

x (

) =

Ft.

wall cap

 

 

 

 

with damper

 

 

 

 

7", 8"

30 Ft.

x (

) =

Ft.

Round,

 

 

 

 

roof cap

 

 

 

 

7” Round to

8 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

7” Round to

15 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

 

Subtotal column 2 =

 

Subtotal column 2 =

 

Total ductwork

 

=

Installation - Ductwork Calculation Sheet

9

Image 9
Contents JAN06.0101 Page Table of Contents Operation Important safety NoticeElectrical & Installation requirements Before Installing the HoodElectrical Requirements List of Materials Parts SuppliedParts not Supplied Dimensions and clearances Installation Instructions Venting MethodsPreparation Installation Ductwork Calculation Sheet Assembling the duct cover support bracket 3 parts InstallationInstallation Hooks Electrical Grounding Instructions Electrical connectionDuct cover support bracket Description of the hood Description of the hood Control Ball Reset filter saturation signalControls Description of control ball and hood operationDescription of the hood Remote Control Using the Remote ControlRemote Control Maintenance Cleaning MaintenanceGrease Filter Replacing the Light BulbShooting Issue Cause What to doTo Obtain Service Under Warranty WarrantyList of Parts and Accessories GF02IAZRC-00SA