Item Description

8A, B, C, D preset buttons

Beeper

Display

9High Limit Reset Switch

10Gas Control Valve Switch

11Drain Lever

12Fill Lever

13Pump Motor Reset Switch

14Rinse Hose Connector

Function

These buttons are used to save and recall preset cycle and alarm times, saving operator time and minimizing error when changing interval cycle times and alarm times. To save the current interval and alarm times into one of the preset locations, press and hold the A, B, C, or D preset button for 2 seconds and the controller will double chirp to indicate the times have been saved. To recall any preset time, press and quickly release the appropriate button and the time values are loaded and displayed. These buttons are also used to reconfigure the STIR OIL function.

A beeper sounds when the timer counts down to 0. Pressing the START/STOP button stops the beeper and resets the timer causing the display to return to the original starting time. At this point, time can be changed using the TIME SELECT buttons or the preset buttons. The beeper will also sound for 10 seconds if the alarm time has elapsed during a timing cycle. When the STIR OIL function begins the beeper will sound until the ALARM or START/STOP button is pressed.

Used to display the time. It also displays the words “STIR” then “OIL” in .5 second intervals until the ALARM or START/STOP button is pressed.

If shortening inside the pot reaches an unsafe temperature, power is automatically removed from the control panel and the gas system shuts off. Pressing this switch returns power to the control panel and resets the gas system.

ON – Allows gas to flow when the FILTER/OFF/FRY switch is set to the FRY position and the thermostat calls for heat.

OFF – Prevents gas flow regardless of FILTER/OFF/FRY switch and thermostat settings.

DRAIN OPEN – When placed in this position, the drain valve opens and shortening drains into the vat. Also power is removed from the control panel and gas system.

DRAIN CLOSED – When placed in this position, the drain valve is closed to prevent shortening from draining into the pot. Also power is restored to the control panel and gas system.

FILL THRU POT – When placed in this position, shortening will be pumped from the vat to the pot if the rocker switch is in the FILTER position.

FILL THRU HOSE – When placed in this position, shortening will be pumped from the vat to the pot via a fill hose if the rocker switch is in the FILTER position.

If the motor overheats while filtering, it will automatically shut off. Wait 15 minutes to allow motor to cool before pressing this switch.

Used to connect the Rinse hose for cleaning and refilling the pot.

14

Image 16
Contents Gas Pressure Fryer Warranty Information Table of Contents Safety Safety Signs and MessagesEquipotential ground plane Specific PrecautionsFull Disconnection Do Not Store Or Use Anything Flammable Near Fryer Safe Work PracticesKeep The Floor Around Your Fryer Clean Shortening Do Not Over-Tighten The Spin Handle Keep Away From The Vent Be Prepared for Emergencies Safety Labels Gas Pressure Fryer Introduction Installation Controls and Indicators OperationItem Description FunctionGas Pressure Fryer Operation LGF and LGF-F Operation Care of the ShorteningStart-Up LGF and LGF-F KEY Display Mode Description Cooking LGF and LGF-FGas Pressure Fryer Operation LGF-FC Operation System ProgrammingStep Action Display Comments Product Programming Product Programming SequenceComments Step Action Display Step Action Display Start-Up LGF-FC Cooking LGF-FCGas Pressure Fryer Operation Recipes Whole Turkey 12 to 14 pounds Whole DucklingPork Chops Cube Or Minute SteaksOperation After Gas or Power Outage Normal ShutoffMaintenance Description Assembly # AssembliesLid/Arm Assembly, AN3211350S Sheet 1 Lid/Arm Assembly, AN3211350S Sheet 2 Lid/Arm Assembly, AN3211350S Sheet 3 Lid/Arm Assembly, AN3211350S Sheet 4 Item # QTY Description Item # QTY Description Drain/Motor/Piping Assembly COUPLING, 5/8 45 Flare to Burner Tray Assembly LP GAS Burner Tray Assembly Control/Insulation Panel LGF & LGF-F BEZEL, Robertshaw Thermostat Control/Insulation Panel LGF -FC CONTROLLER, VFD Less Harness HINGE, DOOR, LH, PIN Side FRY.DOORS Oil Vat Assembly AN32112800 Filter Screen ASSY, LGF Solenoid Valve Assembly Solenoid Valve Assembly Parts BALL, 11/16 Steel Bearing Drain Valve Replacement Accessories Description Accessory #Components Description Component #Wiring Diagram Diagram # Figure #LGF-F 120V/60HZ/1 Phase LGF-FC 120V/60HZ/1 Phase LGF-FC 220V/50HZ/1 Phase LGF-FC 220V/60HZ/1 Phase LGF-FC 240V/50HZ/1 Phase LI0196/0808