Bakers Pride Oven LGF-FC service manual Operation After Gas or Power Outage, Normal Shutoff

Page 29

Gas Pressure Fryer

Operation

Operation After Gas or Power Outage

The fryer may shut off automatically if the gas supply is interrupted or the power goes out. If either of these conditions occur you should perform the following procedure:

For your safety, if the gas supply stops, or, if the power goes out, make sure to wait for at least five minutes before restarting your fryer. This allows time for any unburned gas to dissipate. (LP gas may take longer than five minutes.) If you smell gas, do not start your fryer.

1.Place the gas control ON/OFF switch in the OFF position.

2.Place the FILTER/OFF/FRY switch in the OFF position.

3.Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to escape.

4.Follow normal operating procedures once the power or gas is restored.

Normal Shutoff

1.Place the FILTER/OFF/FRY switch in the OFF position.

2.Place the gas control ON/OFF switch in the OFF position.

3.Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to escape.

27

Image 29
Contents Gas Pressure Fryer Warranty Information Table of Contents Safety Signs and Messages SafetyFull Disconnection Specific PrecautionsEquipotential ground plane Safe Work Practices Do Not Store Or Use Anything Flammable Near FryerKeep The Floor Around Your Fryer Clean Shortening Do Not Over-Tighten The Spin Handle Keep Away From The Vent Be Prepared for Emergencies Safety Labels Gas Pressure Fryer Introduction Installation Operation Controls and IndicatorsFunction Item DescriptionGas Pressure Fryer Operation Start-Up LGF and LGF-F Care of the ShorteningLGF and LGF-F Operation Cooking LGF and LGF-F KEY Display Mode DescriptionGas Pressure Fryer Operation System Programming LGF-FC OperationStep Action Display Comments Product Programming Sequence Product ProgrammingComments Step Action Display Step Action Display Cooking LGF-FC Start-Up LGF-FCGas Pressure Fryer Operation Recipes Whole Duckling Whole Turkey 12 to 14 poundsPork Chops Cube Or Minute SteaksNormal Shutoff Operation After Gas or Power OutageMaintenance Assemblies Description Assembly #Lid/Arm Assembly, AN3211350S Sheet 1 Lid/Arm Assembly, AN3211350S Sheet 2 Lid/Arm Assembly, AN3211350S Sheet 3 Lid/Arm Assembly, AN3211350S Sheet 4 Item # QTY Description Item # QTY Description Drain/Motor/Piping Assembly COUPLING, 5/8 45 Flare to Burner Tray Assembly LP GAS Burner Tray Assembly Control/Insulation Panel LGF & LGF-F BEZEL, Robertshaw Thermostat Control/Insulation Panel LGF -FC CONTROLLER, VFD Less Harness HINGE, DOOR, LH, PIN Side FRY.DOORS Oil Vat Assembly AN32112800 Filter Screen ASSY, LGF Solenoid Valve Assembly Solenoid Valve Assembly Parts BALL, 11/16 Steel Bearing Drain Valve Replacement Description Accessory # AccessoriesDescription Component # ComponentsFigure # Wiring Diagram Diagram #LGF-F 120V/60HZ/1 Phase LGF-FC 120V/60HZ/1 Phase LGF-FC 220V/50HZ/1 Phase LGF-FC 220V/60HZ/1 Phase LGF-FC 240V/50HZ/1 Phase LI0196/0808