Automatic Lift Fryer |
| Operation | |
|
|
|
|
| Table 2. Product Programming Procedure |
| |
|
|
|
|
STEP | ACTION | DISPLAY | COMMENTS |
1 | Press the FILTER/OFF/FRY | LOW |
|
| switch to FRY. |
|
|
2 | Press PROG on the keypad. | PROGRAM CODE |
|
3 | Input 1724 and press ENTER. | PROGRAM PRODUCT # |
|
4 | Select the program product | PROGRAM PRODUCT X | X refers to the program |
| number |
| number you selected. |
5 | Press ENTER. | PROGRAM TIME1 | This command allows you |
|
| 00:00 | to specify the cooking time |
|
|
| for this stage. The time |
|
|
| displayed may be a |
|
|
| previously programmed |
|
|
| value. |
6 | Press TOGGLE/CLEAR and | PROGRAM TIME1 | XX:XX refers to the |
| input the number of minutes you | XX:XX | number of minutes you |
| want to cook. |
| input. |
7 | Press ENTER. | PROGRAM TEMP1 | This command allows you |
|
| 000 °F | to specify the cooking |
|
|
| temperature for this stage. |
|
|
| The temperature displayed |
|
|
| may be a previously |
|
|
| programmed temperature. |
|
|
| The temperature scale |
|
|
| may also display °C |
|
|
| depending on the system |
|
|
| option that is set. |
8 | Press TOGGLE/CLEAR and | PROGRAM TEMP1 | XXX refers to the cooking |
| input the cooking temperature for | XXX °F | temperature you input. |
| product to be cooked. |
|
|
9 | Press ENTER. | PROGRAM TEMPCOM1 | This command enables |
|
| FLEX TIME | you to select whether or |
|
|
| not time is allowed for the |
|
|
| fryer to recover from |
|
|
| temperature loss while |
|
|
| cooking during this stage. |
|
|
| The FLEX TIME option will |
|
|
| allow the fryer to recover |
|
|
| from temperature loss. |
10 | Press TOGGLE/CLEAR until the | PROGRAM TEMPCOM1 | X refers to the |
| desired option is displayed. | X | temperature compensation |
|
|
| option selected. |
11 | Press ENTER. | PROGRAM VALVE1 | This command allows you |
|
| CLOSED | to specify whether the |
|
|
| solenoid valve will be open |
|
|
| or closed during this |
|
|
| stage. |
20