When using the Interface relay contacts to initiate blower operation on a furnace, certain thermostats will initiate the outdoor cooling condenser when R and G are closed.

Use this wiring configuration to prevent the Interface relay contacts from initializing the condenser unit. This problem can occur at the thermostat because the Y terminal is connected to the G terminal internal to the stat. When R and G are closed at the furnace (by dehumidistat or relay) 24 Volts is sent to G at thermostat. 24 Volts is then sent through Y which will initiate outdoor condenser.

Wire

Connector

28

Image 28
Contents RNC Series Introduction Table of ContentsRNC Electronics Dimensions RNC95 Engineering Data HRV Model RNC95Variable Port Location / Installation Model RNC95 only RNC95 Air FlowDimensions RNC155 Engineering Data HRV Model RNC155Dimensions RNC200 Engineering Data HRV Model RNC200Engineering Data HRV Model RNC10 DimensionsRNC10 Engineering Data HRV Model RNC20 RNC20Engineering Data HRV Model RNC5-TPD RNC5-TPDEngineering Data HRV Model RNC120D RNC120DOption 1 Horizontal Duct Configuration Dimensions inches Remote Control Devices Optional Main Control Features ON/OFF SwitchOptional Timers Minute TimerLocating and Suspending the HRV Location Selection Suspending the HRV using Provided Hanging StrapsSuspending the HRV Horizontal Installation Suspending the RNC120DDrain Connections Drain Connection HRV Only Trap HRV onlyInstallation Methods Three Methods of Installation Simplified InstallationsPartially Dedicated Installations Fully Dedicated InstallationsSimplified Installation Return/Return Method Four Port ModelsPartially Dedicated Installation Installation manualFully Dedicated Installation Four Port Models Models RNC155/RNC200Weatherhood Installation Grilles and WeatherhoodsLifebreath Kitchen Grille Lifebreath TechgrilleRemote Control Connections ElectricalChanging OFF to Standby Increasing Low Speed to Medium LowDigital Electronic Timer DET Green LEDDefrost Cycle DIP Switch Settings Increasing the Run Time Factory Setting OptionDamper Defrost 5 port models OFF DFR3Air Flow Balancing Balancing ProcedurePrior to balancing, ensure that Air Flow Balancing Pitot Tube and Gauge DuctPitot Tube Air Flow Balancing Kit Balancing Collar InstructionsProcedure StepStale Air Magnehelic Door Port Balancing KitInterlocking HRV Operation to an Airhandler/Furnace Blower Wiring Diagrams Model RNC5-TPD Defrost DetailsWiring Diagrams RNC120D HRV Control Box Wiring Diagrams RNC95/RNC10/RNC20/RNC155/RNC200 RNC3Troubleshooting Symptom Cause Solution HRV Page

RNC155, RNC20, RNC95, RNC120D, RNC10 specifications

Lifebreath is renowned for its commitment to providing high-quality air ventilation products that enhance indoor air quality. Among its popular models are the RNC95, RNC5-TPD, RNC155, RNC10, and RNC200, each offering unique features and technologies tailored to different ventilation needs.

The Lifebreath RNC95 is known for its efficient performance, featuring a high-efficiency heat exchanger that recovers up to 95% of the energy from outgoing air. This model is perfect for residential use, where energy efficiency is paramount. The compact design allows for easy installation, and it is equipped with advanced controls that enable smart operation, ensuring optimal air quality with minimal energy consumption.

On the other hand, the RNC5-TPD is designed for tight spaces without compromising on performance. It provides a versatile solution with a variable speed motor that adjusts airflow to match the specific requirements of the environment. This model also features a quick-change filter system, making maintenance a breeze. Its energy recovery capabilities help reduce heating and cooling costs, appealing to eco-conscious consumers.

The RNC155 stands out due to its robust capacity, catering to larger living spaces or commercial environments. This unit integrates advanced airflow management technology, allowing users to balance air distribution effectively throughout the building. The unit's energy-efficient operation is complemented by integrated controls that can be programmed for optimal performance based on occupancy and air quality levels.

The RNC10 offers a budget-friendly option while maintaining effective ventilation. It is compact and lightweight, making it ideal for smaller rooms or apartments. Despite its size, it features a reliable heat recovery system that significantly lowers energy costs and enhances comfort.

Finally, the RNC200 is a powerhouse model designed for larger commercial spaces. It boasts an impressive airflow capacity, making it suitable for demanding environments. This unit includes sophisticated monitoring systems that provide real-time data on air quality and system performance, ensuring that the air remains fresh and healthy. Additionally, its customizable setup allows for integration with other HVAC systems, further enhancing its functionality.

In summary, Lifebreath models like RNC95, RNC5-TPD, RNC155, RNC10, and RNC200 exemplify cutting-edge ventilation technology. Their distinct features cater to various needs, from residential to commercial applications, ensuring that users enjoy optimal indoor air quality while minimizing energy expenditure.