Drain Connections

Drain Connection (HRV Only)

During a defrost cycle, the HRV may produce some condensation. This water should flow into a nearby drain, or be taken away by a condensate pump.

CAUTION

The HRV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point or freeze protection must be provided.

The HRV cabinet has prepunched holes for the drain (see below). Insert the drain spout through the hole in the drain pan. Do not forget the “O ring” which seals each spout to the pan REMEMBER TO HAND TIGHTEN ONLY the washer and lock nut which hold the drain spout in place.

Construct a P-Trap using the plastic tee connector. Cut two lengths of hose and connect each piece to an end of the “T” fitting, then connect the other ends to the two drain spouts. Position the “T” fitting to point upward and connect the drain line. Tape or fasten base to avoid any kinks. Pour a cup of water into the drain pan of the HRV after the drain connection is complete. This creates a water seal which will prevent odors from being drawn up the hose and into the fresh air supply of the HRV.

"P" Trap (HRV only)

DRAIN HOSE PLUMBING

PRE-PUNCHED HOLES (2)

 

DRAIN PAN

DRAIN PAN

 

DRAIN

 

DRAIN

SPOUT

 

 

SPOUT

 

 

ZIP TIE

TEE

1/2 " I.D.

 

CONNECTOR

DRAIN HOSE

 

TO DRAIN

 

HARD PIPE PLUMBING

 

PRE-PUNCHED HOLES (2)

 

DRAIN PAN

DRAIN PAN

 

DRAIN

1/2" HARD PIPE

DRAIN

 

SPOUT

 

SPOUT

TEE

 

TO DRAIN

JOINT

 

Model RNC120D

Drain Set-up for Vertical Installation

CAUTION

Drain trap and tubing MUST be below bottom of door with 1/4" per foot downwards slope away from unit.

Note: Secondary drain pan may be required to protect from condensate leakage.

Do not remove

cap from drain spout

1/2” I.D. condensate line

Use “T” between drain pans to create a “P Trap”. “P” trap must be at least 6” (152 mm) below unit.

Drain Set-up for Horizontal Installation

Do not remove these drain plugs

1/2” I.D.

Use drain spout provided in condensate line door. “P” trap must be at least

6” (152 mm) below unit.

15

Image 15
Contents RNC Series Table of Contents IntroductionRNC Electronics Engineering Data HRV Model RNC95 Dimensions RNC95RNC95 Air Flow Variable Port Location / Installation Model RNC95 onlyEngineering Data HRV Model RNC155 Dimensions RNC155Engineering Data HRV Model RNC200 Dimensions RNC200Dimensions Engineering Data HRV Model RNC10RNC10 RNC20 Engineering Data HRV Model RNC20RNC5-TPD Engineering Data HRV Model RNC5-TPDRNC120D Engineering Data HRV Model RNC120DOption 1 Horizontal Duct Configuration Dimensions inches Minute Timer Remote Control Devices Optional Main Control FeaturesON/OFF Switch Optional TimersSuspending the HRV using Provided Hanging Straps Locating and Suspending the HRV Location SelectionSuspending the HRV Suspending the RNC120D Horizontal InstallationTrap HRV only Drain Connections Drain Connection HRV OnlyFully Dedicated Installations Installation Methods Three Methods of InstallationSimplified Installations Partially Dedicated InstallationsFour Port Models Simplified Installation Return/Return MethodInstallation manual Partially Dedicated InstallationFour Port Models Models RNC155/RNC200 Fully Dedicated InstallationLifebreath Techgrille Weatherhood InstallationGrilles and Weatherhoods Lifebreath Kitchen GrilleIncreasing Low Speed to Medium Low Remote Control ConnectionsElectrical Changing OFF to StandbyGreen LED Digital Electronic Timer DETOFF DFR3 Defrost Cycle DIP Switch Settings Increasing the Run TimeFactory Setting Option Damper Defrost 5 port modelsBalancing Procedure Air Flow BalancingPrior to balancing, ensure that Balancing Collar Instructions Air Flow Balancing Pitot Tube and GaugeDuct Pitot Tube Air Flow Balancing KitStep ProcedureMagnehelic Door Port Balancing Kit Stale AirInterlocking HRV Operation to an Airhandler/Furnace Blower Defrost Details Wiring Diagrams Model RNC5-TPDWiring Diagrams RNC120D HRV Control Box RNC3 Wiring Diagrams RNC95/RNC10/RNC20/RNC155/RNC200Troubleshooting Symptom Cause Solution HRV Page

RNC155, RNC20, RNC95, RNC120D, RNC10 specifications

Lifebreath is renowned for its commitment to providing high-quality air ventilation products that enhance indoor air quality. Among its popular models are the RNC95, RNC5-TPD, RNC155, RNC10, and RNC200, each offering unique features and technologies tailored to different ventilation needs.

The Lifebreath RNC95 is known for its efficient performance, featuring a high-efficiency heat exchanger that recovers up to 95% of the energy from outgoing air. This model is perfect for residential use, where energy efficiency is paramount. The compact design allows for easy installation, and it is equipped with advanced controls that enable smart operation, ensuring optimal air quality with minimal energy consumption.

On the other hand, the RNC5-TPD is designed for tight spaces without compromising on performance. It provides a versatile solution with a variable speed motor that adjusts airflow to match the specific requirements of the environment. This model also features a quick-change filter system, making maintenance a breeze. Its energy recovery capabilities help reduce heating and cooling costs, appealing to eco-conscious consumers.

The RNC155 stands out due to its robust capacity, catering to larger living spaces or commercial environments. This unit integrates advanced airflow management technology, allowing users to balance air distribution effectively throughout the building. The unit's energy-efficient operation is complemented by integrated controls that can be programmed for optimal performance based on occupancy and air quality levels.

The RNC10 offers a budget-friendly option while maintaining effective ventilation. It is compact and lightweight, making it ideal for smaller rooms or apartments. Despite its size, it features a reliable heat recovery system that significantly lowers energy costs and enhances comfort.

Finally, the RNC200 is a powerhouse model designed for larger commercial spaces. It boasts an impressive airflow capacity, making it suitable for demanding environments. This unit includes sophisticated monitoring systems that provide real-time data on air quality and system performance, ensuring that the air remains fresh and healthy. Additionally, its customizable setup allows for integration with other HVAC systems, further enhancing its functionality.

In summary, Lifebreath models like RNC95, RNC5-TPD, RNC155, RNC10, and RNC200 exemplify cutting-edge ventilation technology. Their distinct features cater to various needs, from residential to commercial applications, ensuring that users enjoy optimal indoor air quality while minimizing energy expenditure.