Lifebreath RNC95, RNC5-TPD, RNC200, RNC10 Partially Dedicated Installation, Installation manual

Page 18

The Partially Dedicated Installation

Stale air drawn from key areas of home (bathroom, kitchen, laundry)

Fresh air supplied to return air duct of air handler

FOUR PORT MODELS

WARNING

HRV must be balanced.

Refer to “Airflow Balancing” in this manual.

DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN

(Stale air drawn from key areas of home)

EXHAUST AIR from various parts of home.

i.e. bathrooms (if required), kitchens (if required).

Return Air

Outdoors

* Unit is normally balanced on HIGH speed

with furnace blower ON.

3' (1 m) min . recommended

Cool Air

Return

NOTES:

1.Furnace blower is recommended to operate when HRV is on to provide good air distribution.

2.Weatherhood arrangement is for drawing purposes only. 6' (2 m) minimum separation required. 18" (460 mm) above grade minimum.

3.Due to the differences in pressure between the HRV and the equipment it is being connected to, the HRV's airflow must be confirmed on site, using the balancing procedure found in

the installation manual.

4.The duct port configuration (Fresh Air from Outside, Stale Air to Outside, etc.) varies from model to model. Check specifications for the duct configuration on your model.

Forced Air

Furnace

FIVE PORT MODELS - Partially Dedicated Installation for Models RNC10/RNC20

Outdoors

Stale Air To Outside

Return Air

3' (1 m) min . recommended

Fresh Air From Outside

Cool Air

Return

STALE AIR from various parts of home.

i.e. bathrooms (if required), kitchens (if required).

Field-supplied

Balancing Damper

High efficiency filter

Air

Handler

(optional)

WARNING

Defrost air port needs to be drawn from clean area without combustion appliances. To avoid backdrafting of combustion products, never draw defrost air from a room with a naturally aspirated appliance, i.e. furnace, hot water heater, gas dryer, stove, fire place etc.

or electronic air cleaner

*Unit is normally balanced on HIGH speed

with furnace blower ON.

CAUTION

Weatherhood arrangement - requires a minimum of 6' (2m) separation and a minimum of 18" (460mm) clearance above grade or anticipated snow level.

18

Image 18
Contents RNC Series Table of Contents IntroductionRNC Electronics Dimensions RNC95 Engineering Data HRV Model RNC95Variable Port Location / Installation Model RNC95 only RNC95 Air FlowDimensions RNC155 Engineering Data HRV Model RNC155Dimensions RNC200 Engineering Data HRV Model RNC200Dimensions Engineering Data HRV Model RNC10RNC10 Engineering Data HRV Model RNC20 RNC20Engineering Data HRV Model RNC5-TPD RNC5-TPDEngineering Data HRV Model RNC120D RNC120DOption 1 Horizontal Duct Configuration Dimensions inches Optional Timers Remote Control Devices Optional Main Control FeaturesON/OFF Switch Minute TimerSuspending the HRV using Provided Hanging Straps Locating and Suspending the HRV Location SelectionSuspending the HRV Horizontal Installation Suspending the RNC120DDrain Connections Drain Connection HRV Only Trap HRV onlyPartially Dedicated Installations Installation Methods Three Methods of InstallationSimplified Installations Fully Dedicated InstallationsSimplified Installation Return/Return Method Four Port ModelsPartially Dedicated Installation Installation manualFully Dedicated Installation Four Port Models Models RNC155/RNC200Lifebreath Kitchen Grille Weatherhood InstallationGrilles and Weatherhoods Lifebreath TechgrilleChanging OFF to Standby Remote Control ConnectionsElectrical Increasing Low Speed to Medium LowDigital Electronic Timer DET Green LEDDamper Defrost 5 port models Defrost Cycle DIP Switch Settings Increasing the Run TimeFactory Setting Option OFF DFR3Balancing Procedure Air Flow BalancingPrior to balancing, ensure that Pitot Tube Air Flow Balancing Kit Air Flow Balancing Pitot Tube and GaugeDuct Balancing Collar InstructionsProcedure StepStale Air Magnehelic Door Port Balancing KitInterlocking HRV Operation to an Airhandler/Furnace Blower Wiring Diagrams Model RNC5-TPD Defrost DetailsWiring Diagrams RNC120D HRV Control Box Wiring Diagrams RNC95/RNC10/RNC20/RNC155/RNC200 RNC3Troubleshooting Symptom Cause Solution HRV Page

RNC155, RNC20, RNC95, RNC120D, RNC10 specifications

Lifebreath is renowned for its commitment to providing high-quality air ventilation products that enhance indoor air quality. Among its popular models are the RNC95, RNC5-TPD, RNC155, RNC10, and RNC200, each offering unique features and technologies tailored to different ventilation needs.

The Lifebreath RNC95 is known for its efficient performance, featuring a high-efficiency heat exchanger that recovers up to 95% of the energy from outgoing air. This model is perfect for residential use, where energy efficiency is paramount. The compact design allows for easy installation, and it is equipped with advanced controls that enable smart operation, ensuring optimal air quality with minimal energy consumption.

On the other hand, the RNC5-TPD is designed for tight spaces without compromising on performance. It provides a versatile solution with a variable speed motor that adjusts airflow to match the specific requirements of the environment. This model also features a quick-change filter system, making maintenance a breeze. Its energy recovery capabilities help reduce heating and cooling costs, appealing to eco-conscious consumers.

The RNC155 stands out due to its robust capacity, catering to larger living spaces or commercial environments. This unit integrates advanced airflow management technology, allowing users to balance air distribution effectively throughout the building. The unit's energy-efficient operation is complemented by integrated controls that can be programmed for optimal performance based on occupancy and air quality levels.

The RNC10 offers a budget-friendly option while maintaining effective ventilation. It is compact and lightweight, making it ideal for smaller rooms or apartments. Despite its size, it features a reliable heat recovery system that significantly lowers energy costs and enhances comfort.

Finally, the RNC200 is a powerhouse model designed for larger commercial spaces. It boasts an impressive airflow capacity, making it suitable for demanding environments. This unit includes sophisticated monitoring systems that provide real-time data on air quality and system performance, ensuring that the air remains fresh and healthy. Additionally, its customizable setup allows for integration with other HVAC systems, further enhancing its functionality.

In summary, Lifebreath models like RNC95, RNC5-TPD, RNC155, RNC10, and RNC200 exemplify cutting-edge ventilation technology. Their distinct features cater to various needs, from residential to commercial applications, ensuring that users enjoy optimal indoor air quality while minimizing energy expenditure.