TC electronic SDN BHD D22 user manual Frequently Asked Questions, Examples

Page 29

FREQUENTLY ASKED QUESTIONS

Question: What parameters can be set using serial remote control of the D22?

Answer: Preset change, Delay time and Bypass using an RS485/422/232 controller.

Question: What serial protocol is used?

Answer: The serial protocol is 9600, N, 8, 1.

This means 9.6 kbaud, no parity, 8 bit, 1 stop.

Question: What is the command structure for the remote protocol?

Answer: #AA,CMD,VALUE<CR>

AAis Unit Address number as set on the Utility page. CMD is command:

PRE for preset change, BYP for Bypass, DEL for delay.

VALUE is (RAM) Preset number, 0 for Not Bypass, 1 for Bypass or amount of Delay.

<CR> is carriage return, the same as Enter or hex 0D.

Examples:

 

#05,PRE,10<CR>

=Recall RAM preset no. 10 on D22 address 5.

#03,BYP,1<CR>

=Bypass D22 address 3.

All commands and numbers are shown as ASCII.

Question: What is the data length of the delay time?

Answer: The delay is always a decimal number related to the given delay unit of the D22. It is not posible to change delay unit via the RS-485, so you must set this manually before you send the command lines.

Example 1:

The delay unit is ms and you would like to set the delay to 10.5 ms: #05,DEL,10.5<CR>

Example 2:

The delay unit is frames and you would like to set the delay to 10.5 frames: #05,DEL,10.5<CR>

As you can see there is no difference between example 1 and 2. Example 3: The delay unit is ms and you would like to set the delay to 10.5 frames:

You have to calculate the delay in ms yourself based on the fps setting and then send a command-line.

Question: What ASCII characters should be sent for Recall of RAM preset no. 10 on D22 address 5?

Answer: #05,PRE,10<CR> means these values (hex) actually transmitted 23 30 35 2C 50 52 45 2C 31 30 0D

27

Image 29
Contents USER’S Manual Page Service Important Safety InstructionsCertificate Of Conformity For the customers in CanadaTable of Contents Page Introduction Main FeaturesFront Panel Power & Memory Card Electronic Power switch »Easy touch«Bypass Jack unbalanced XLR Output Balanced XLR XLR Rear PanelSignal path is 24 bit Signal FlowInstallation note SetupsInput Analog Output Analog Input AnalogInput Digital Sample Rate Sync Sample Rate Conversion On Input Analog Sample Rate SyncInput Digital Sample Rate EXT DI Basic Operation Keyboard Lock Function Control Adjust wheelBypass Bypasses the unit Recall Recalling a presetPresets In General Fader Locked modeSeamless preset changes Store Storing User PresetsUsing a Memory card Sample Rate Conversion SetupClock DitherDigital I/O Press the I/O key twice to enter this AnalogAnalog Out Control Resolution Time ResolutionTap Delay UtilityMeter Memory BackupGPI External Input No sound through the D22 Preset changes are not seamlessYou cannot turn the power off Appendix Technical specifications Battery test Delay + Control wheel testService note Key test Tos-link Sys-Ex System Exclusive Midi Commands Bits & Bytes Compressor OvershootFader Cable Midi CablePedal Cable Jack unbalanced XLR Output Jack balanced XLR Examples Frequently Asked QuestionsConnecting and Calibrating the Master Fader Why make a Master Fader?Master Fader Activating the Master Fader