SWRA004A
Low-Band Cascaded: RF Input Return Loss
Control state: 011000
The input return loss of the low band receiver is measured at the EVM low band RF input port, J10. The measurement is performed using a network analyzer.
Set up the network analyzer as follows to measure the RF input return loss:
1)Set the network analyzer to measure the low band RF frequency (see Table 3).
2)Set the power range to
3)Perform a full
4)Set the network analyzer to measure S11.
5)Connect the EVM RF input, J10, to port 1 of the network analyzer.
6)Measure the RF input return loss.
Low-Band Cascaded: LO Input Return Loss
Control state: 011000
The cascaded LO input return loss of the Low Band is measured at the EVM low band LO input port, J12. The measurement is performed using a network analyzer.
1)Set the network analyzer to measure the low band LO frequency (see Table 3).
2)Set the power range to
3)Perform a full
4)Set the network analyzer to measure S11.
5)Connect the EVM LO input port, J12, to port 1 of the network analyzer.
6)Measure the LO input return loss.
30 | TRF1500 Integrated |