3.Fresh Air Fireplace Exhaust - Stale air/combustion products from the FAF to the HRV Duct Materials: CoolVent™ Flexible Pipe (1” air clearance to combustible materials)

Firestops, Hangers and Accessories as Required a. Fresh Air Fireplace Exhaust Guidelines

1)FAF must be vented with CoolVent™ flexible insulated vent pipe, maintaining 1” (25.4mm) clearance to combustible

 

￿￿

￿

￿￿￿￿￿

￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿

 

surfaces.

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1” (25.4mm) air clearance to combustibles must be maintained

 

 

 

 

 

 

when using CoolVent™ in this portion of the venting system.

 

 

 

2)

The total combined length of the CoolVent™ run for the Fireplace Exhaust and the HRV Exhaust must not exceed the

 

maximum lengths shown in the following table:

 

 

 

 

 

 

3)

Direction of flow may include any combination horizontal, vertical up or vertical down.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

 

￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿

 

 

 

4)The entire vent run must be contained within an area which will not experience temperatures below 40°F.

WARNING!

The maximum TOTAL EXHAUST vent run is measured from the flue collar of the Fresh Air Fire- place, through the HRV, to the outside termination. DO NOT EXCEED MAXIMUM VENTING LENGTHS!

b.Attaching the CoolVent™ to the Fresh Air Fireplace Flue Collar

1)Secure a CoolVent™ appliance connector to the CoolVent™ insulated flexible pipe per the manufacturer’s instructions.

2)Apply a generous bead (1/2 inch) of RTV high temperature silicone to the flue collar and attach the appliance adaptor.

c.Assembling the Vent Pipe Sections

1)When it is necessary to connect two or more lengths of CoolVent™ insulated flexible pipe in a vent run, use a universal connector at each joint.

2)Always support CoolVent™ insulated flexible pipe every three feet.

WARNING!

When vent sections exceed three feet (.9m) in length ensure minimum clearances are maintained. Structural support must be provided to reduce off-center loading. Follow manufacturer installation instructions..

14

4034-102 Rev F

02/04

Image 14
Contents Installation & Operating Instructions Heat Recovery VentilatorTable of Contents HRV200PLUS ApplicationEngineering Data Appliance Dimensions HRV200PLUS Clearance to CombustiblesNo Defrost Defrost OptionsChoose the defrost method best for your application Room Air Defrost Setup for Room Air Defrost OptionSetup for Fresh Air Fireplace Defrost Option Fresh Air Fireplace DefrostInstallation Diagrams Simplified Installation Supply/Return MethodFresh Air Partially Dedicated InstallationExhaust Air Fully Dedicated Installation Location Installing the VentilatorInstalling the Drain Line and P-Trap ElectricalStandard Vent and Duct InstallationOptional Alternate Exhaust Damper Assembly Locate the Fresh Air InletInstall Fresh Air Supply Ducting Duct the Warmside Air SupplyWarmside Ducting Guidelines Dampers and GrillesAssembling the Vent Pipe Sections HRV Plus Exhaust Guidelines Horizontal Exhaust Terminations see Figures Exhaust TerminationStale Air from the Living Area to the HRV Alternate Exhaust Alternate Exhaust PortHorizontal Termination Typical Horizontal TerminationTermination Cap Locations Dimension Descriptions As specified in CGA B149 Installation CodesVertical Termination see Figure Typical Vertical Termination see FigureTypical Vertical Termination Chase/Termination Installation Vent HeightFirestop Spacer/Vent Installation Installing the Firestop SpacerSelecting Blower Speeds Net Air Flow sCFMAir Flow Balancing BalancingBalancing Collar Instructions Pitot Tube Balancing Procedure see Figure Pitot Tube Balancing Flow Station Balancing Procedure see Figure Flow Station BalancingFireplace High Fire Mode Fireplace Operating Modes Connector P9OFF Mode Operating Modes∅ d. Novus Plus/6000 Plus Initiation HRV Defrost ModeTermination Fireplace Control Terminals Thermostat Operating Modes Connector P6Thermostat on Mode Ventilation Operating Modes Connector P1 Ventilation Control Terminals Connector P1Furnace Interface Terminals Furnace Interface Operating Modes Connector P3Interlock Mode ∅ Caliber NXT Plus or 6100 Plus & HRV Wired Together WiringFireplace Control Wiring ∅ Novus Plus Control Wiring ∅ 6000 Plus Control Wiring Hvac System Thermostat Control Wiring Thermostat Control WiringVentilation Control Wiring Ventilation Control WiringFurnace Interface Wiring Furnace Interface WiringQuarterly Maintenance Maintenance InstructionsMonthly Maintenance Inspect Exterior Hoods Semi Annual Maintenance Clean CoreInspect and Clean Drain condensate Lines if required Annual MaintenanceGeneral Maintenance Inspect and Clean Duct Work if requiredSummarized Guide 20+3 77.58!$% Accessories Installing Remote ControlsREPLACEMENT-#$###$+*#!,&#PARTS#$% Index AHRHRV200PLUS GAS Appliance Limited Warranty

HRV200PLUS specifications

The Hearth and Home Technologies HRV200PLUS is an advanced heat recovery ventilator (HRV) designed to provide optimal indoor air quality while ensuring energy efficiency. As homes become increasingly airtight due to modern construction techniques, the importance of proper ventilation grows. The HRV200PLUS addresses this need by continuously exchanging stale indoor air with fresh outdoor air, effectively maintaining a healthy living environment.

One of the standout features of the HRV200PLUS is its innovative heat recovery technology. This system captures the heat from the outgoing air and transfers it to the incoming fresh air. As a result, the air being brought into the home is pre-warmed, reducing the demand on heating systems during the colder months. This energy-efficient method helps homeowners save on heating costs while maintaining comfort levels inside the home.

Another notable characteristic of the HRV200PLUS is its quiet operation. Equipped with high-performance, low-noise fans, this unit operates in silence, ensuring that occupants can enjoy a peaceful environment without the disruptive sounds often associated with ventilation systems. Additionally, the HRV200PLUS provides versatile installation options, allowing it to be easily integrated into both new and existing homes.

The unit features adjustable settings that allow users to customize airflow according to their specific needs. With multiple fan speeds, homeowners can choose the most suitable option for their daily activities, ensuring an ideal balance between indoor air quality and energy use. Furthermore, the HRV200PLUS includes a built-in filter system that captures dust, allergens, and other airborne particles, enhancing overall air quality.

Durability and ease of maintenance are also keys in the design of the HRV200PLUS. Constructed with high-quality materials, this unit is made to last, reducing the need for frequent replacements. The filters are easily accessible, making periodic maintenance straightforward, which further extends the product's lifespan.

In summary, the Hearth and Home Technologies HRV200PLUS stands out as a premium choice for homeowners seeking a reliable and efficient ventilation solution. Its combination of heat recovery technology, quiet operation, customizable settings, and easy maintenance make it an ideal option for improving indoor air quality while keeping energy costs in check. As the emphasis on healthy living spaces continues to grow, the HRV200PLUS remains a practical investment for modern homes.