4.Annual Maintenance

a.Inspect and Clean Drain (condensate) Lines (if required)

Inspect the drain line, drain spout and P-trap for blockage, mold or kinks. Flush with warm soapy water. Replace if worn, bent or if you are unable to clean.

b.Inspect and Clean Duct Work (if required)

The duct work running to and from the HRV200PLUS may accumulate dirt. Wipe and vacuum the duct once every year. You may wish to contact a heating/ventilation company to do this.

c.Inspect and Clean the Fans (if required)

Note: Before attempting the following task, thought should be given to having a qualified service technician complete the service work.

Fans may accumulate dirt causing an imbalance and/or excessive vibration of the HRV200PLUS. A reduction in the air flow may also occur. In new construction this may result within the first year due to heavy dust and may occur periodically over time depending on the outdoor conditions.

1)Unplug the HRV200PLUS and open the service door.

2)Remove the core.

3)Remove the ducting (metal and/or flexible insulated type) from the black ports which are connected immediately inline with the fan assembly.

4)Use a small brush, such as an old toothbrush or pipe cleaner and insert it:

a)Through the large opening of the fan assembly, and then

b)Through the smaller opening in the end of the fan assembly.

5)Scrub the individual fan blades until clean. Avoid moving or damaging balancing flat weight. The clip is usually found on one or more of the fan blades.

6)Vacuum and wipe.

7)Reassemble making sure the ducting is reattached firmly and the insulation and moisture barrier are sealed and taped.

5.General Maintenance

Wipe down the inside of the cabinet with a damp cloth to remove dirt, bugs and debris that may be present.

40

4034-102 Rev F

02/04

Image 40
Contents Installation & Operating Instructions Heat Recovery VentilatorTable of Contents HRV200PLUS ApplicationEngineering Data Appliance Dimensions HRV200PLUS Clearance to CombustiblesChoose the defrost method best for your application Defrost OptionsNo Defrost Setup for Room Air Defrost Option Setup for Fresh Air Fireplace Defrost OptionRoom Air Defrost Fresh Air Fireplace DefrostInstallation Diagrams Simplified Installation Supply/Return MethodExhaust Air Partially Dedicated InstallationFresh Air Fully Dedicated Installation Installing the Ventilator Installing the Drain Line and P-TrapLocation ElectricalVent and Duct Installation Optional Alternate Exhaust Damper AssemblyStandard Locate the Fresh Air InletInstall Fresh Air Supply Ducting Duct the Warmside Air SupplyWarmside Ducting Guidelines Dampers and GrillesAssembling the Vent Pipe Sections HRV Plus Exhaust Guidelines Exhaust Termination Stale Air from the Living Area to the HRV Alternate ExhaustHorizontal Exhaust Terminations see Figures Alternate Exhaust PortHorizontal Termination Typical Horizontal TerminationTermination Cap Locations Dimension Descriptions As specified in CGA B149 Installation CodesVertical Termination see Figure Typical Vertical Termination see FigureTypical Vertical Termination Chase/Termination Installation Vent HeightFirestop Spacer/Vent Installation Installing the Firestop SpacerSelecting Blower Speeds Net Air Flow sCFMBalancing Collar Instructions BalancingAir Flow Balancing Pitot Tube Balancing Procedure see Figure Pitot Tube Balancing Flow Station Balancing Procedure see Figure Flow Station BalancingFireplace Operating Modes Connector P9 OFF ModeFireplace High Fire Mode Operating ModesTermination HRV Defrost Mode∅ d. Novus Plus/6000 Plus Initiation Thermostat on Mode Thermostat Operating Modes Connector P6Fireplace Control Terminals Ventilation Operating Modes Connector P1 Ventilation Control Terminals Connector P1Interlock Mode Furnace Interface Operating Modes Connector P3Furnace Interface Terminals Fireplace Control Wiring Wiring∅ Caliber NXT Plus or 6100 Plus & HRV Wired Together ∅ Novus Plus Control Wiring ∅ 6000 Plus Control Wiring Hvac System Thermostat Control Wiring Thermostat Control WiringVentilation Control Wiring Ventilation Control WiringFurnace Interface Wiring Furnace Interface WiringMaintenance Instructions Monthly Maintenance Inspect Exterior HoodsQuarterly Maintenance Semi Annual Maintenance Clean CoreAnnual Maintenance General MaintenanceInspect and Clean Drain condensate Lines if required Inspect and Clean Duct Work if requiredSummarized Guide 20+3 77.58!$% Accessories Installing Remote ControlsREPLACEMENT-#$###$+*#!,&#PARTS#$% Index AHRHRV200PLUS GAS Appliance Limited Warranty

HRV200PLUS specifications

The Hearth and Home Technologies HRV200PLUS is an advanced heat recovery ventilator (HRV) designed to provide optimal indoor air quality while ensuring energy efficiency. As homes become increasingly airtight due to modern construction techniques, the importance of proper ventilation grows. The HRV200PLUS addresses this need by continuously exchanging stale indoor air with fresh outdoor air, effectively maintaining a healthy living environment.

One of the standout features of the HRV200PLUS is its innovative heat recovery technology. This system captures the heat from the outgoing air and transfers it to the incoming fresh air. As a result, the air being brought into the home is pre-warmed, reducing the demand on heating systems during the colder months. This energy-efficient method helps homeowners save on heating costs while maintaining comfort levels inside the home.

Another notable characteristic of the HRV200PLUS is its quiet operation. Equipped with high-performance, low-noise fans, this unit operates in silence, ensuring that occupants can enjoy a peaceful environment without the disruptive sounds often associated with ventilation systems. Additionally, the HRV200PLUS provides versatile installation options, allowing it to be easily integrated into both new and existing homes.

The unit features adjustable settings that allow users to customize airflow according to their specific needs. With multiple fan speeds, homeowners can choose the most suitable option for their daily activities, ensuring an ideal balance between indoor air quality and energy use. Furthermore, the HRV200PLUS includes a built-in filter system that captures dust, allergens, and other airborne particles, enhancing overall air quality.

Durability and ease of maintenance are also keys in the design of the HRV200PLUS. Constructed with high-quality materials, this unit is made to last, reducing the need for frequent replacements. The filters are easily accessible, making periodic maintenance straightforward, which further extends the product's lifespan.

In summary, the Hearth and Home Technologies HRV200PLUS stands out as a premium choice for homeowners seeking a reliable and efficient ventilation solution. Its combination of heat recovery technology, quiet operation, customizable settings, and easy maintenance make it an ideal option for improving indoor air quality while keeping energy costs in check. As the emphasis on healthy living spaces continues to grow, the HRV200PLUS remains a practical investment for modern homes.