HRV200PLUS INSTALLATION INSTRUCTIONS

2.Room Air Defrost

a.When the HRV200PLUS system is installed in climates that normally have more than five days a year with an outside temperature below 25°F, Room Air Defrost is the recommended defrost method for two reasons:

1)Unanticipated fireplace ignition due to the HRV200PLUS entering the defrost cycle is eliminated, and

2) This presents the opportunity for some homeowners to remove the fixed mesh screen or screen door retainers on the front of the Caliber NXT Plus or the 6100 PLUS allowing true “open hearth” operation.

b.Setup for Room Air Defrost Option

1)Install the HRV200PLUS and the Fresh Air Fireplace per the instructions in this manual.

2)Install the Optional Defrost Kit (part # HRV99DEFKIT). The Optional Defrost Assembly is microprocessor controlled to efficiently perform all defrost functions independently of the HRV200PLUS.

3)Ensure the DEFC1 jumper is installed on the HRV control board. This jumper will disable the defrost logic in the HRV200PLUS.

3.Fresh Air Fireplace Defrost

When the HRV200PLUS system is installed in climates that normally have more than five days a year with outside temperatures below 25°F, Fresh Air Fireplace Defrost is a desirable defrost method because it utilizes the heat from the Fresh Air Fireplace to clear any frost build-up on the heat recovery core. However, the following precautions should be noted:

a.This method does allow the HRV200PLUS to independently ignite the Fresh Air Fireplace which may result in unexpected fireplace operation.

b. The fixed mesh screen or screen door retainers on the Caliber NXT Plus and the 6100 PLUS fronts must not be removed when using the Fresh Air Fireplace Defrost option.

c.Setup for Fresh Air Fireplace Defrost Option

1)Install the HRV200PLUS and the Fresh Air Fireplace per the instructions in this manual.

2)Remove the DEFC12 jumper on the HRV control board. Removing this jumper will allow the HRV200PLUS to control the Fresh Air Fireplace for defrost cycles.

6

4034-102 Rev F

02/04

Image 6
Contents Installation & Operating Instructions Heat Recovery VentilatorTable of Contents HRV200PLUS ApplicationEngineering Data Appliance Dimensions HRV200PLUS Clearance to CombustiblesDefrost Options Choose the defrost method best for your applicationNo Defrost Room Air Defrost Setup for Room Air Defrost OptionSetup for Fresh Air Fireplace Defrost Option Fresh Air Fireplace DefrostInstallation Diagrams Simplified Installation Supply/Return MethodPartially Dedicated Installation Exhaust AirFresh Air Fully Dedicated Installation Location Installing the VentilatorInstalling the Drain Line and P-Trap ElectricalStandard Vent and Duct InstallationOptional Alternate Exhaust Damper Assembly Locate the Fresh Air InletInstall Fresh Air Supply Ducting Duct the Warmside Air SupplyWarmside Ducting Guidelines Dampers and GrillesAssembling the Vent Pipe Sections HRV Plus Exhaust Guidelines Horizontal Exhaust Terminations see Figures Exhaust TerminationStale Air from the Living Area to the HRV Alternate Exhaust Alternate Exhaust PortHorizontal Termination Typical Horizontal TerminationTermination Cap Locations Dimension Descriptions As specified in CGA B149 Installation CodesVertical Termination see Figure Typical Vertical Termination see FigureTypical Vertical Termination Chase/Termination Installation Vent HeightFirestop Spacer/Vent Installation Installing the Firestop SpacerSelecting Blower Speeds Net Air Flow sCFMBalancing Balancing Collar InstructionsAir Flow Balancing Pitot Tube Balancing Procedure see Figure Pitot Tube Balancing Flow Station Balancing Procedure see Figure Flow Station BalancingFireplace High Fire Mode Fireplace Operating Modes Connector P9OFF Mode Operating ModesHRV Defrost Mode Termination∅ d. Novus Plus/6000 Plus Initiation Thermostat Operating Modes Connector P6 Thermostat on ModeFireplace Control Terminals Ventilation Operating Modes Connector P1 Ventilation Control Terminals Connector P1Furnace Interface Operating Modes Connector P3 Interlock ModeFurnace Interface Terminals Wiring Fireplace Control Wiring∅ Caliber NXT Plus or 6100 Plus & HRV Wired Together ∅ Novus Plus Control Wiring ∅ 6000 Plus Control Wiring Hvac System Thermostat Control Wiring Thermostat Control WiringVentilation Control Wiring Ventilation Control WiringFurnace Interface Wiring Furnace Interface WiringQuarterly Maintenance Maintenance InstructionsMonthly Maintenance Inspect Exterior Hoods Semi Annual Maintenance Clean CoreInspect and Clean Drain condensate Lines if required Annual MaintenanceGeneral Maintenance Inspect and Clean Duct Work if requiredSummarized Guide 20+3 77.58!$% Accessories Installing Remote ControlsREPLACEMENT-#$###$+*#!,&#PARTS#$% Index AHRHRV200PLUS GAS Appliance Limited Warranty

HRV200PLUS specifications

The Hearth and Home Technologies HRV200PLUS is an advanced heat recovery ventilator (HRV) designed to provide optimal indoor air quality while ensuring energy efficiency. As homes become increasingly airtight due to modern construction techniques, the importance of proper ventilation grows. The HRV200PLUS addresses this need by continuously exchanging stale indoor air with fresh outdoor air, effectively maintaining a healthy living environment.

One of the standout features of the HRV200PLUS is its innovative heat recovery technology. This system captures the heat from the outgoing air and transfers it to the incoming fresh air. As a result, the air being brought into the home is pre-warmed, reducing the demand on heating systems during the colder months. This energy-efficient method helps homeowners save on heating costs while maintaining comfort levels inside the home.

Another notable characteristic of the HRV200PLUS is its quiet operation. Equipped with high-performance, low-noise fans, this unit operates in silence, ensuring that occupants can enjoy a peaceful environment without the disruptive sounds often associated with ventilation systems. Additionally, the HRV200PLUS provides versatile installation options, allowing it to be easily integrated into both new and existing homes.

The unit features adjustable settings that allow users to customize airflow according to their specific needs. With multiple fan speeds, homeowners can choose the most suitable option for their daily activities, ensuring an ideal balance between indoor air quality and energy use. Furthermore, the HRV200PLUS includes a built-in filter system that captures dust, allergens, and other airborne particles, enhancing overall air quality.

Durability and ease of maintenance are also keys in the design of the HRV200PLUS. Constructed with high-quality materials, this unit is made to last, reducing the need for frequent replacements. The filters are easily accessible, making periodic maintenance straightforward, which further extends the product's lifespan.

In summary, the Hearth and Home Technologies HRV200PLUS stands out as a premium choice for homeowners seeking a reliable and efficient ventilation solution. Its combination of heat recovery technology, quiet operation, customizable settings, and easy maintenance make it an ideal option for improving indoor air quality while keeping energy costs in check. As the emphasis on healthy living spaces continues to grow, the HRV200PLUS remains a practical investment for modern homes.