Zanussi ZCG560G user manual Flexible nonmetal pipes connection, Gas burners, Type of gas

Page 13

Gas burners

BURNER

Auxiliary burner

Semi-rapid burner

Rapid burner

Oven

NORMAL POW-

ER

kW

1,00

1,00

0,85

2,00

2,00

1,70

3,00

3,00

2,60

2,70

2,50

2,15

REDUCED

POWER

kW

0,35

0,35

0,31

0,43

0,43

0,40

0,72

0,72

0,63

0,90

0,90

0,78

Type of gas

Natural gas

G20

Butane G30

Propane G31

Natural gas

G20

Butane G30

Propane G31

Natural gas

G20

Butane G30

Propane G31

Natural gas

G20

Butane G30

Propane G31

Pressure

mbar

20

50

50

20

50

50

20

50

50

20

50

50

Inj. diameter

mm

0,70

0,43

0,43

0,96

0,60

0,60

1,19

0,77

0,77

1,20

0,63

0,63

Cons.

g/h

-

72,71

60,70

-

145,43

121,40

-

181,78

157,11

-

196,33

162,82

Gas Connection

Choose fixed connections or use a flexible pipe in stain- less steel in compliance with the regulation in force. If you use flexible metallic pipes, be careful they do not come in touch with mobile parts or they are not squeezed.

When you install and connect the appliance, obey the directives:

SVGW- Gas principles G1: Gas installation

EKAS- Form. 1942: Liquid gas directive, Part 2

Cantonal instances regulations (e.g. fire safety regula- tors)

Flexible nonmetal pipes connection

If it is possible to easily control the connection in its full area, you can use a flexible pipe. The flexible pipe must be tightly attached by clamps.

Installation: use the pipe holder. Always engage the gas- ket. Then continue with the gas connection. The flexible pipe is prepared for apply when:

www.zanussi.com

it can not get hot more than room temperature, higher than 30°C;

it is no longer than 1500 mm;

it shows no throttles;

it is not subject to traction or torsion;

it does not get in touch with cutting edges or corners;

it can be easily examined in order to check its condi- tion.

The control of preservation of the flexible pipe consists in checking that:

it does not show cracks, cuts, marks of burnings on the two ends and on its full length;

the material is not hardened, but shows its correct elasticity;

the fastening clamps are not rusted;

expired term is not due.

If one or more defects are visible, do not repair the pipe, but replace it.

13

Image 13
Contents ZCG560G Safety information ContentsLid UseDo not apply pressure on the open door Service centre Care and cleaningProduct description Disposal of the applianceHob Daily use Before first useHob Helpful hints and tips Hob Care and cleaningTurning the burner off Energy savingsOven Functions Oven Daily useGas oven cooking Turning off the oven burnerOven Helpful hints and tips Oven Using the accessoriesInserting the baking tray Baking cakesCooking times Cleaning the oven door Oven Care and cleaningInformation on acrylamides Possible cause What to do if…Remedy Minimal distances InstallationLocation of the appliance By-pass diametersGas burners Flexible nonmetal pipes connectionType of gas Pressure Mbar Inj. diameter ConsInjectors replacement Adjustment to different types of gasAdjustment of minimum level Oven injector replacementEnvironment concerns Adjustment of the ad Justment screwLevelling GasServicestellen Points de Service CH Garantie, Garanzia, GuaranteeCucina/Vendita Page Page Page 892942646-D-452011