Tricity Bendix TBG700 user manual Type of GAS

Page 14

BURNER

RAPID

SEMI-RAPID A U X I L I A R Y TRIPLECROWN

TYPE OF GAS

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

M A X

MIN

M A X

MIN

M A X

MIN

M A X

MIN

 

NOMINAL THERMAL

kW

3 . 0

0.65

2 . 0

0.45

1 . 0

0.33

4 . 0

1 . 2

NATURAL GAS

POWER

 

 

 

 

 

 

 

 

 

 

 

20 mbar

NOMINAL FLOW

m3/h

0.286

0.062

0.190

0.043

0.095

0.031

0.381

0.114

VALUE =

RATE

37.78 MJ/m3

NOZZLE REFERENCE

119

Adjust.

9 6

Adjust.

7 0

Adjust.

146

Adjust.

Ws - 50.7 MJ/ m3

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

LPG GAS

NOMINAL THERMAL

kW

2 . 8

0.65

2 . 0

0.45

1 . 0

0.33

4 . 0

1 . 2

POWER

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

VALUE =

g/h

202

4 7

144

3 2

7 2

2 4

288

8 6

RATE

49.92 MJ/Kg

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

8 6

4 0

7 1

3 2

5 0

2 8

9 8

5 6

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

Auxiliary28

Semi-rapid 32

Rapid40

Triple crown

56

Aeration adjustment none

14

Image 14
Contents TBG700 Welcome to the world of Electrolux Contents Child Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hob Installation Hob burners control knobs Using the hob correctlyOperation Lighting the burnersBurner Minimum Maximum Diameter Pan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Cut Out Size Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Fitting the Hob into the Worktop Electrical Connections This HOB Must be EarthedWiring Diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions Service and Spare Parts European Guarantee Page 35674-6903 02/07 R.0