Tricity Bendix TBG700 user manual Earth Continuity Check

Page 24

A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight.

B.INSULATION CHECK

Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

24

Image 24
Contents TBG700 Welcome to the world of Electrolux Contents Important Safety Information InstallationChild Safety During UseService Environmental InformationDescription of the Hob Installation Using the hob correctly OperationHob burners control knobs Lighting the burnersBurner Minimum Maximum Diameter Maintenance and Cleaning Hob TopPan Supports Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Cut Out Size Building Building over a cupboard or drawerBuilding over a kitchen unit with door Fitting the Hob into the Worktop Electrical Connections This HOB Must be EarthedWiring Diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions Service and Spare Parts European Guarantee Page 35674-6903 02/07 R.0