Tricity Bendix TBG700 user manual Commissioning, Pressure Testing

Page 26

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

1)Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

1)Re-ignite the burner and set to MIN.

2)Remove the control knob.

3) To adjust, use a thin bladed

 

screwdriver and turn the adjustment

 

screw (see diagram) until the flame

 

is steady and does not extinguish,

 

when the knob is turned from MIN

 

to MAX. Repeat this procedure for

Minimum adjustment screw

all burners.

 

Pressure Testing

The pressure testing must becarried out on the burners.

Proceed as follows:

1)Remove the pan supports and the burner caps and crowns.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar.

4)Turn off the burner supplies.

26

Image 26
Contents TBG700 Welcome to the world of Electrolux Contents Child Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hob Installation Hob burners control knobs Using the hob correctlyOperation Lighting the burnersBurner Minimum Maximum Diameter Pan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Cut Out Size Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Fitting the Hob into the Worktop Electrical Connections This HOB Must be EarthedWiring Diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions Service and Spare Parts European Guarantee Page 35674-6903 02/07 R.0