Tricity Bendix TBG700 user manual Wiring Diagram, Permanent Connection

Page 22

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

Wiring Diagram

L

1

N

220 1

240

2

3

4

0 5

2

1.Ignitor switches

2.Ignitor unit

22

Image 22
Contents TBG700 Welcome to the world of Electrolux Contents Child Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hob Installation Hob burners control knobs Using the hob correctlyOperation Lighting the burnersBurner Minimum Maximum Diameter Hob Top Maintenance and CleaningPan Supports Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Cut Out Size Building over a cupboard or drawer BuildingBuilding over a kitchen unit with door Fitting the Hob into the Worktop Electrical Connections This HOB Must be EarthedWiring Diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing CommissioningConversion from Natural Gas to LPG MethodStandard Guarantee Conditions Service and Spare Parts European Guarantee Page 35674-6903 02/07 R.0