Frigidaire LCRT2010ST Record Keeping and Notification After Measurement, Special TIP

Page 12

MEASUREMENT WITH OUTER CASE REMOVED

When you replace the magnetron, measure for microwave energy leakage before the outer case is installed and after all necessary components are replaced or adjusted.

Special care should be taken in measuring the following parts. (Circled area of Fig. below)

-Around the magnetron

-The waveguide

WARNING : AVOID CONTACTING ANY HIGH VOLTAGE PARTS

MEASUREMENT WITH A FULLY ASSEMBLED OVEN

After all components, including the outer case, are fully assembled, measure for microwave energy leakage around the door viewing window, the exhaust opening, and air inlet openings.

Microwave energy leakage must not exceed the values prescribed below.

NOTE : Leakage with the outer case removedless than 5 mW/cm.sq. Leakage for a fully assembled oven (Before the latch switch (primary) is interrupted) with the door in a slightly opened position-less than 2 mW/cm.sq.

NOTES WHEN MEASURING

Do not exceed meter full scale deflection.

The test probe must be removed no faster than

1 inch/sec (2.5 cm/sec) along the shaded area, otherwise a false reading may result.

The test probe must be held with the grip portion of the handle.

A false reading may result if the operator's hand is befween the handle and the probe.

When testing near a corner of the door, keep the probe perpendicular to the surface making sure the probe horizontally along the oven surface.Hold vertically when testing the top and bottom,and horizontally along.

RECORD KEEPING AND NOTIFICATION AFTER MEASUREMENT

After adjustment and repair of any microwave energy interruption or microwave energy blocking device, record the measured values for future reference. Also enter the information on the service invoice.

The microwave energy leakage should not be more than 4 mW/cm.sq. after determining that all parts are in good condition, functioning properly and genuine replacement parts which are listed in this manual have been used.

At least once a year, have the electromagnetic energy leakage monitor checked for calibration by its manufacturer.

SPECIAL TIP

• This oven used the button head screws.

Button Head (Torx style 2)

• When you remove the screws, use

the tamper-resistant Torx driver having a pin-in-head.

5-2

Image 12
Contents Microwave Oven Safety Precautions Microwave RadiationContents Specifications DescriptionMicrowave Radiation AntennaInstallations InstallingGrounding Instructions Features Operating InstructionsControl Panel Operating Sequence Schematic Diagram Circuit Description General DetailsService Information Tools and Measuring InstrumentsMicrowave Leakage Test Record Keeping and Notification After Measurement Special TIPMeasurement of Microwave Power Output Disassembly and AdjustmentPower Supply Cord Control Panel AssemblyPCB Assembly Removal Door Main Assembly / RemovalAIR Duct Assembly / Removal Magnetron RemovalRemoving Sensor FAN Motor Assembly Removal Removing the Turntable MotorHigh Voltage Transformer Removal High Voltage Capacitor and Diode RemovalInterlock System Interlock MechanismPrimary Interlock Switch Test Secondary Interlock Switch TestMonitor Switch Test Components Test Procedure ResultsComponent Test Procedure Components Test ProcedureFilament Winding Primary Terminal MagnetronHigh Voltage CapacitorDiode Power RelayLevel FAN MotorTrouble Shooting Condition Cause RemedyCondition Check Result CauseMalfunction of secondary switch Condition Check Result Cause RemedySetting time does not count down when touching Start pad Check Result Exploded View IntroductionDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts Interior Parts 50FZZABase Plate Parts Sensor Parts