Frigidaire LCRT2010ST service manual Check Result

Page 26

(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run. (Display operates properly)

CONDITION

No microwave oscillation.

CHECK

 

 

 

RESULT

 

 

 

 

 

 

 

 

 

 

Disconnect the

 

 

 

No continuity.

 

 

 

wire leads from

 

 

 

 

 

 

 

 

relay 2 and

 

 

 

 

 

 

 

 

check continuity

 

 

 

Continuity.

 

 

 

of relay2.

 

 

 

 

 

 

 

 

(Operate the unit)

 

 

 

 

 

 

 

 

 

CAUSE

Defective PCB assembly

REMEDY

Replace PCB assembly

Check high vol-

Abnormal

tage transformer

 

normal

Check high vol-

Abnormal

tage capacitor.

 

normal

Check high vol-

Abnormal

tage diode.

 

normal

Defective high voltage transformer.

Defective high voltage capacitor.

Defective high voltage diode.

Replace high voltage transformer.

Replace high voltage capacitor.

Replace high voltage diode.

Check

Abnormal

Defective

Magnetron.

magnetron.

 

Replace magnetron.

NOTE: • Make sure the wire leads correct position.

When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.

When removing the magnetron, be sure to install the magnetron gasket in the correct position and in good condition.

Output is full power when you set lower power level.

Disconnect the wire leads from relay 2 and check continuity relay 2. (Operate the unit)

Abnormal.

Defective PCB assembly

Replace PCB assembly

5-16

Image 26
Contents Microwave Oven Safety Precautions Microwave RadiationContents Specifications DescriptionMicrowave Radiation AntennaGrounding Instructions InstallationsInstalling Control Panel FeaturesOperating Instructions Operating Sequence Schematic Diagram Circuit Description General DetailsMicrowave Leakage Test Service InformationTools and Measuring Instruments Record Keeping and Notification After Measurement Special TIPPower Supply Cord Measurement of Microwave Power OutputDisassembly and Adjustment Control Panel AssemblyPCB Assembly Removal Door Main Assembly / RemovalRemoving Sensor AIR Duct Assembly / RemovalMagnetron Removal High Voltage Transformer Removal FAN Motor Assembly RemovalRemoving the Turntable Motor High Voltage Capacitor and Diode RemovalInterlock System Interlock MechanismMonitor Switch Test Primary Interlock Switch TestSecondary Interlock Switch Test Components Test Procedure ResultsFilament Winding Primary Terminal Component Test ProcedureComponents Test Procedure MagnetronDiode High VoltageCapacitor Level PowerRelay FAN MotorTrouble Shooting Condition Cause RemedyCondition Check Result CauseMalfunction of secondary switch Condition Check Result Cause RemedySetting time does not count down when touching Start pad Check Result Exploded View IntroductionDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts Interior Parts 50FZZABase Plate Parts Sensor Parts