Frigidaire LCRT2010ST Condition Check Result Cause Remedy, Malfunction of secondary switch

Page 24

(TROUBLE 2) Oven does not operate at all, Display window does not display any figures, and no input is accepted.

CONDITION

CHECK

RESULT

CAUSE

REMEDY

1. Fuse blows.

Check continuity of monitor switch (with door closed).

Replace fuse

Continuity.

No continuity.

Malfunction of the monitor switch.

Replace fuse, primary, monitor, secondary switches, and RELAY(RY2) of P.C.B Assembly.

Check continuity

Continuity.

of primary

 

switch (with

 

door opened)

No continuity.

 

Check continuity

Continuity.

of secondary

 

switch (with

 

door opened).

No continuity.

 

Disconnect one

Normal.

side of the wire

 

lead connected

 

from transformer

Fuse blows again

to the high

 

voltage

 

capacitor and

 

operate the unit.

 

Shorted contact at the primary switch.

Malfunction of secondary switch.

Defective high voltage capacitor.

Defective high volt- age transformer.

Replace fuse, primary, monitor, secondary switches, and RELAY(RY2) of P.C.B Assembly.

Replace fuse, primary, monitor, secondary switches, and RELAY(RY2) of P.C.B Assembly.

Replace high voltage capacitor.

Replace high volt- age transformer.

NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8

2.Fuse does not blow.

Check continuity of thermostat.

No continuity.

Defective thermostat.

Replace thermostat.

 

Continuity.

 

 

Check continuity

No continuity.

Defective power

Replace power

of power supply

supply cord.

supply cord.

 

cord.

 

 

 

5-14

Image 24
Contents Microwave Oven Safety Precautions Microwave RadiationContents Specifications DescriptionMicrowave Radiation AntennaInstallations InstallingGrounding Instructions Features Operating InstructionsControl Panel Operating Sequence Schematic Diagram Circuit Description General DetailsService Information Tools and Measuring InstrumentsMicrowave Leakage Test Record Keeping and Notification After Measurement Special TIPMeasurement of Microwave Power Output Disassembly and AdjustmentPower Supply Cord Control Panel AssemblyPCB Assembly Removal Door Main Assembly / RemovalAIR Duct Assembly / Removal Magnetron RemovalRemoving Sensor FAN Motor Assembly Removal Removing the Turntable MotorHigh Voltage Transformer Removal High Voltage Capacitor and Diode RemovalInterlock System Interlock MechanismPrimary Interlock Switch Test Secondary Interlock Switch TestMonitor Switch Test Components Test Procedure ResultsComponent Test Procedure Components Test ProcedureFilament Winding Primary Terminal MagnetronHigh Voltage CapacitorDiode Power RelayLevel FAN MotorTrouble Shooting Condition Cause RemedyCondition Check Result CauseMalfunction of secondary switch Condition Check Result Cause RemedySetting time does not count down when touching Start pad Check Result Exploded View IntroductionDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts Interior Parts 50FZZABase Plate Parts Sensor Parts