INTERLOCK CONTINUITY TEST

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.

TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH TYPE NO.SZM-V 16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH

A. PRIMARY INTERLOCK SWITCH TEST

When the door release button is depressed slowly with the door closed, an audible click should be heard at the same time or successively at intervals. When the button is released slowly, the latches should activate the switches with an audible click.

If the latches do not activate the switches when the door is closed, the switches should be a adjusted in accordance with the adjustment procedure. Disconnect the wire lead from the primary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminal of the switch. The meter should indicate an open circuit in the door open condition. When the door is closed, the meter should indicate a closed circuit.

When the primary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

B. SECONDARY INTERLOCK SWITCH TEST

Disconnect the wire lead from the secondary switch.

Connect the ohmmeter leads to the common (COM) and normally open (NO) terminals of the switch. The meter should indicate a open circuit in the door open condition. When the door is closed, meter should indicate an closed circuit. When the secondary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

C. MONITOR SWITCH TEST

Disconnect the wire lead from the monitor switch. Connect the ohmmeter leads to the common (COM) and normally closed (NC) terminals of the switch. The meter should indicate closed circuit in the door open condition. When the door is closed, meter should indicate an open circuit. When the monitor switch operation is abnormal, replace with the same type of switch.

NOTE: After repairing the door or the interlock system, it is necessary to do this continuity test before operating the oven.

COMPONENTS

 

TEST PROCEDURE

RESULTS

SWITCHES

Check for continuity of the

Door

Door

(Wire leads removed)

switch with an Ohm-meter

open

closed

 

Primary

 

 

 

 

Switch

NO

 

 

 

COM

 

 

 

Monitor

NC

 

 

 

Switch

 

 

 

COM

 

 

 

Secondary

 

 

 

 

Switch

COM

 

 

 

 

NO

 

 

 

NOTE : After checking for the continuity of switches, make sure that they are

 

connected correctly.

 

 

5-8

Image 18
Contents Microwave Oven Safety Precautions Microwave RadiationContents Specifications DescriptionMicrowave Radiation AntennaInstallations InstallingGrounding Instructions Features Operating InstructionsControl Panel Operating Sequence Schematic Diagram Circuit Description General DetailsService Information Tools and Measuring InstrumentsMicrowave Leakage Test Record Keeping and Notification After Measurement Special TIPPower Supply Cord Measurement of Microwave Power OutputDisassembly and Adjustment Control Panel AssemblyPCB Assembly Removal Door Main Assembly / RemovalAIR Duct Assembly / Removal Magnetron RemovalRemoving Sensor High Voltage Transformer Removal FAN Motor Assembly RemovalRemoving the Turntable Motor High Voltage Capacitor and Diode RemovalInterlock System Interlock MechanismMonitor Switch Test Primary Interlock Switch TestSecondary Interlock Switch Test Components Test Procedure ResultsFilament Winding Primary Terminal Component Test ProcedureComponents Test Procedure MagnetronHigh Voltage CapacitorDiode Level PowerRelay FAN MotorTrouble Shooting Condition Cause RemedyCondition Check Result CauseMalfunction of secondary switch Condition Check Result Cause RemedySetting time does not count down when touching Start pad Check Result Exploded View IntroductionDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts Interior Parts 50FZZABase Plate Parts Sensor Parts