Frigidaire LCRT2010ST AIR Duct Assembly / Removal, Magnetron Removal, Removing Sensor

Page 15

F. AIR DUCT ASSEMBLY / REMOVAL

1)Disconnect the leadwire from lamp.

2)Remove the mounting screw to the magnetron.

G. MAGNETRON REMOVAL

1)Disconnect the leadwire from themagnetron.

2)Carefully remove the mounting screws holding the magnetron to the waveguide.

3)Remove the magnetron ASS’Y until the tube is clear from the waveguide.

NOTE:

1.When removing the magnetron, make sure its dome does not hit any adjacent parts, or it may be damaged.

2.When replacing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition.

3.After replacing the magnetron, check for microwave leakage with a survey meter around the magnetron. Microwave energy must be below the limit of 5 mW/cm2. (With a 275 ml. water load).

Make sure that gasket is rigidly attached to the magnetron. To prevent microwave leakage, tighten the mounting screws properly, making sure there is no gap between the waveguide and the magnetron.

Alr duct

Magnetron

Waveguide

Dome

Waveguide

Bracket

Magnetron

Gasket

Magnetron

G. REMOVING SENSOR

1)Disconnect the leadwire from PCB Assembly.

2)Remove a screw securing the sensor duct.

5-5

Image 15
Contents Microwave Oven Microwave Radiation Safety PrecautionsContents Description SpecificationsAntenna Microwave RadiationInstallations InstallingGrounding Instructions Features Operating InstructionsControl Panel Operating Sequence Schematic Diagram General Details Circuit DescriptionService Information Tools and Measuring InstrumentsMicrowave Leakage Test Special TIP Record Keeping and Notification After MeasurementControl Panel Assembly Measurement of Microwave Power OutputDisassembly and Adjustment Power Supply CordDoor Main Assembly / Removal PCB Assembly RemovalAIR Duct Assembly / Removal Magnetron RemovalRemoving Sensor High Voltage Capacitor and Diode Removal FAN Motor Assembly RemovalRemoving the Turntable Motor High Voltage Transformer RemovalInterlock Mechanism Interlock SystemComponents Test Procedure Results Primary Interlock Switch TestSecondary Interlock Switch Test Monitor Switch TestMagnetron Component Test ProcedureComponents Test Procedure Filament Winding Primary TerminalHigh Voltage CapacitorDiode FAN Motor PowerRelay LevelCondition Cause Remedy Trouble ShootingCheck Result Cause ConditionCondition Check Result Cause Remedy Malfunction of secondary switchSetting time does not count down when touching Start pad Check Result Introduction Exploded ViewDoor Parts Controller Parts Oven Cavity Parts Latch Board Parts 50FZZA Interior PartsBase Plate Parts Sensor Parts