Frigidaire 318205403 installation instructions Bare or, Green Wire, Listed, Cable from appliance

Page 4

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

This appliance is manufactured with a frame connected green (or bare copper) ground wire.

DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.

If your appliance is not equipped with a white neutral conductor:

Connect only to a 3-wire, 120/240V power supply; the neutral conductor is not required for the operation of the appliance. The potential at the power supply electrical connections shall be 150V to ground or less.

NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-recognized for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor is governed by

Where local codes permit connecting the appliance-grounding conductor to the neutral (white) wire (USA only):

Your appliance has a 3-wire cable to be connected to a 3-wire grounded junction box (see figure 4):

1.Disconnect the power supply.

2.In the circuit breaker, fuse box or junction box:

Connect appliance and power supply cable wires as shown in figure 4.

Cable from Power Supply

Ground Wire

Red

WiresBlack

Wires

the temperature rating of the insulation around the wire,

Ground Wire

Junction Box

rather than the wire gauge alone.

RISK OF ELECTRIC SHOCK: Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; recreational vehicules; or in Canada, or in an area where local codes prohibit grounding through the neutral connector.

(If your appliance is equipped with a white neutral conductor.)

This appliance is manufactured with a white neutral power supply and a frame connected copper wire. The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit, if used in USA, in a new branch circuit installation (1996 NEC), mobile home, recreational vehicles, where local code do not permit grounding trough the neutral (white) wire or in Canada, disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes, connect neutral lead to branch circuit-neutral conductor in usual manner see Figure 6 or 7. If your appliance is to

be connected to a 3 wire grounded junction box (US only), where local code permit connecting the appliance-grounding conductor to the neutral (white) see Figure 4 or 5.

(Bare or

U.L.-Listed Conduit

Green Wire)

Connector (or CSA

 

listed)

Cable from appliance

Figure 4 – U.S.A. Only

3-WIRE GROUNDED JUNCTION BOX

Your appliance has a 4-wire cable to be connected to a 3-wire grounded junction box (see figure 5):

1.Disconnect the power supply.

2.In the junction box:

Connect appliance and power supply cable wires as shown in Figure 5.

Cable from Power Supply

Ground Wire

 

Black

 

Wires

 

 

Red Wires

 

 

 

 

Junction

 

 

Box

 

 

White Wire

Ground Wire

 

U.L.-Listed Conduit

 

Connector (or CSA listed)

(Bare or Green Wire)

Cable from appliance

 

 

 

Figure 5 – U.S.A. Only

3-WIRE GROUNDED JUNCTION BOX

4

Image 4
Contents Model Important INSTALLATION‑INFORMATION Width Depth Length Below MIN MAX Important Notes to the Installer Important Note to the ConsumerObserve all governing codes and local ordinances Unpacking InstructionsUnder cooktop Green Wire Wire Grounded Junction BOXBare or ListedConduit CSA listed Cable from applianceCooktop Installation All Ceramic-Glass CooktopsSet the cooktop into the countertop cutout Models 26 and 36 36 X 18 Coil Elements CooktopsBefore You Call for Service Checking OperationModel and Serial Number Location Models 32 Coil Elements CooktopsCutout Dimensions Depth HeightDimensiones DE Recortado Información Importante Para LA InstalaciónModelo Longitud Anchura MAX MINNotas importantes para el instalador Nota importante al consumidorInstrucciones de desembalaje Conexión eléctricaRiesgo DE Descarga Eléctrica La conexión a Riesgo de choque eléctricoCaja DE Empalmes DE 3 Alambres Puesta a Tierra Verde o Rojos Negros Caja de Empalmes Alambre ve rde Conductor deDesnudo Cable de la estufa CSA Cable desde el suministro de energía Alambre desnudoInstalación de la estufa TornillosEspaciadores EstufaRevisión de operación Ubicación del número de modelo y de serieAntes de llamar al servicio Modelos 32 con resistencias espiralesDimensiones DE Abertura Anchura Profundidad Altura CON Tapa DE Cocina MontadaDimensions DE Découpage Instructions DE Sécurité ImportantesModèle Longueur Largeur MIN MAXInstallateur ConsommateurInstructions de déballage Modèles vitrocéramiques seulementLa mise à la terre de cet appareil est obligatoire Fil dénudé ConnecteurOu vert Ou Acnor Câble de lappareil Fils rouges Boîte de Jonction Fil dénudé Fil blanc Ou vertFil dénudé Fils Ou vert RougesBoîte de jonction Canadien norme Acnor C22.1, Partie 1 Figure Installation de la plaque de cuissonModèles de plaque de cuisson 32 avec éléments spiraux Emplacement des numéros de modèle et de série Vérification de fonctionnementDimensions DE Louverture Largeur Profondeur Hauteur Pour réduire lesRisques de blessures Pour retenir le four Encastré à larmoire