CARE AND CLEANING
(continued)
CAUTION: DO NOT OPERATE THE BURNER WITHOUT ALL BURNER PARTS AND DRIP PANS (IF SO EQUIPPED) IN PLACE.
Sealed Burner Assemblies (on some models)
Grate
Burner cap
Drip pan
(on some models)
Burner head
Electrode
Turn all controls OFF before removing the burner parts and drip pans (if so equipped).
The burner grates, caps, burner heads and drip pans (if so equipped) can be lifted off, making them easy to clean.
The electrode of |
|
the spark igniter is | Electrode |
exposed when the |
|
burner head is |
|
removed. When one |
|
burner is turned to LITE, all the burners spark. Do not attempt to disassemble or clean around any burner while another burner is on. An electric shock may result, which could cause you to knock over hot cookware.
Burner Heads (on sealed burners only)
NOTE: Before removing the burner heads and caps, remember their size and location. Replace them in the same location after cleaning.
For proper ignition,
make sure the small hole in the section that fits over the electrode is kept open. A sewing needle or wire
The slits in the burner heads of your range must be kept clean at all times for an even, unhampered flame.
You should clean the surface burners routinely, especially after bad spillovers, which could clog these openings.
To remove
Before putting the burner head back, shake out excess water and then dry it thoroughly by setting it in a warm oven for 30 minutes.
Replace the burner heads and caps. Make sure that the heads and
caps are replaced in the correct location. There is one small, 2 medium and one large head and cap.
NOTE: On some models the burner heads and caps are all the same size and can be used in any of the 4 needed locations.
Burner Caps (on sealed burners only)
Lift off when cool. Wash burner caps in hot, soapy water and rinse with clean water. You may scour with a plastic scouring pad to remove
Dry them in a warm oven or with a
Make sure that caps are replaced on the correct size burner. There is one small, 2 medium and one large cap.
22
small | medium | small |
| ||
medium |
|
|
large | medium | large |
|
| |
|
| Front of Range |
NOTE: On some models the caps are all the same size and can be used in any of the 4 needed locations.